Plant Engineering Infobase · Questions from practice
Questions from practice: AutoCAD P&ID
154 questions about AutoCAD P&IDR&I – Piping and instrumentation diagram Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram). Background and sources › from our training courses and support – with the answer from practice. Free and without login.
AutoCAD P&ID (154)
How do I back up my customized interface so it doesn't get lost?
First set up palettes, toolbars, the menu barbar – Unit of pressure Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”). Background and sources › and options. Then, via the gear icon in the status bar or the workspace selector in the Quick Access Toolbar, choose "Save Current As". It is advisable to keep the name of the original workspace and append your own abbreviation, e.g. "P&ID ISOISO – International Organization for Standardization International Organization for Standardization in Geneva: it develops standards that apply worldwide (ISO standards). Background and sources › AB". This preserves the original, and you can see which workspace yours is based on. Save again after, for example, switching the palette group – otherwise changes are lost the next time you open Customize User Interface.
After copying, objects show a question mark instead of a number. Why – and how do I assign new tags?
A tag may occur only once in the project; a copy would get the same number, so the program sets a "?". Right-click the object at its edge and choose "Assign Tag"; the button next to the number assigns the next available number. If you have already placed the annotation, deactivate "Place annotation after assigning tag" – otherwise a second annotation is created, which you then select and delete. Preferably copy with the COPY command instead of Ctrl+C/Ctrl+V and use a crossing window (from right to left) so that connected lines are copied as well.
How do I record revision states and restore older drawing versions?
A proven approach: plot every issue as a PDFPDF – Portable Document Format File format for documents that looks the same on every device and can be printed – e.g. the piping class sheet. Background and sources ›, with the revision index in the file name and title block. In addition, back up the entire project at each revision point – with the project closed, copy the project folder or store it as a ZIPZIP – ZIP archive Compressed archive containing several files in one file. Windows opens it without additional software, e.g. catalog and pipe spec for Plant 3D. Background and sources › with the date in the name. You can retrieve individual drawings from it via "Copy Drawings to Project". If, on the other hand, you only swap DWGDWG – AutoCAD drawing format AutoCAD file format for drawings and 3D models; AutoCAD Plant 3D and AutoCAD P&ID also save in this format. Background and sources › files in the project folder, the drawing and the project database no longer match.
Why should the project name not contain spaces or special characters?
When you create a project, the project name is also used as the name of the project folder. Spaces, special characters and very long paths can later cause problems with access, copying or backups. A proven approach is a project number with a short name and underscores, e.g. "2026_001_Pumpstation". Enter the full project description in the Description field of the wizard – spaces are no problem there and the text can be changed at any time. Also, do not create projects in synchronized cloud folders, as creating them there can take a very long time.
How can I tell whether a line is correctly connected to equipment?
A plus sign at the end of a line means: not connected. When connected correctly, a nozzle is placed and annotated automatically. For a grid-accurate connection, use Shift + right-click > "Apparent Intersection" and click the line and the equipment outline. In P&ID, preferably use the object snaps Nearest, Node and, if needed, Perpendicular – Endpoint and Midpoint often lead to connections off the grid.
The Project Wizard is not displayed correctly or crashes – what could be the cause?
A common cause is Windows display scaling above 100% (e.g. 125%). Right-click the desktop > Display settings, set scaling to 100%, sign out of Windows and back in, and restart AutoCAD P&ID or Plant 3D. The wizard is then usually displayed in full.
The flow arrows point in the wrong direction. How do I reverse the flow direction?
The flow direction results from the direction in which the line was drawn. Right-click the line and choose Schematic Line Edit > Reverse Flow. The arrows are flipped and the line's From/To information is adjusted. Then hover over the line: the tooltip shows from which object to which object the line runs. Validation also shows you flow direction conflicts.
How do I remove part of a line or insert a gap at a crossing?
Right-click the line > "Schematic Line Edit": 1. "Break" – click the break point once and confirm with Enter; then select only the superfluous section and delete it. 2. "Join" puts separated parts back together. 3. "Add Gap" inserts a break at a crossing. You do not remove a gap by deleting the symbol but via "Remove Gap". 4. "Reverse Flow" reverses the flow direction.
Where do I enter the project information that should appear in the title block?
In the Project Manager, right-click the project name (top level) and choose the last entry in the context menu (Project Setup). Under "Project Details", fill in the fields used in the title block and in lists. There you can also enable the prompt for the edit history – a comment on the change is then requested when saving. The first time, also check whether the path to the drawing template (DWTDWT – Drawing template AutoCAD template file (drawing template): new drawings take their layers, styles and settings from it. Background and sources ›) is accessible.
How do I organize the symbols in my P&ID tool palette so I can quickly find my own or modified symbols?
Drag the symbols to the desired position by drag and drop – also between palettes or groups. Insert separators via the palette's context menu; this lets you form symbol groups and sort them as needed.
How do I place a valve with actuator and fail-safe position in the P&ID?
Place the shut-off valve from the In-Line Objects onto the line and assign a tag; in the following dialog, select and assign the actuator (e.g. diaphragm); in the next menu, select the fail-safe position.
My tool palette has disappeared or shows the wrong symbols. How do I get it back?
Press Ctrl+3 or use Tools > Palettes > Tool Palettes to show the palette again (Properties: Ctrl+1). If it shows the wrong symbols, right-click the title bar of the palette and select the palette group that matches the project, e.g. the ISO group. The palette must match the symbol standard the project was created with – symbols from different standards are generally not interchangeable. It is best to dock the palette at the edge of the screen and then save your workspace.
May I open P&ID drawings by double-clicking in Explorer or copy them with "Save As"?
No. Plant drawings belong to a project with a database and should be created, opened, and closed only via the Project Manager. “Save As” creates a copy of the drawing with the same objects – as a result, entries can be counted twice in the project and bills of materials become wrong. Save only with Ctrl+S. Create new drawings by right-clicking “P&ID Drawings” > New Drawing, not via the plus tab. To reuse an existing drawing, use “Copy Drawings to Project” in the Project Manager. Related support question: “How do I bring P&ID drawings from an older project into a new one?” In the Project Manager, right-click “P&ID Drawings” > “Copy Drawings to Project” and select the DWG from the old project. This way no project files need to be reworked – drawings copied in Explorer, by contrast, are not cleanly part of the project.
How do I copy P&ID content into another drawing without losing properties?
Copy with a base point: select the objects, press Ctrl+Shift+C, enter base point 0,0, then in the target drawing press Ctrl+V and enter 0,0 again. With a simple Ctrl+C/Ctrl+V, the P&ID properties are not reliably carried over. Within a drawing, use the AutoCAD COPY command. For similar P&IDs, create a new drawing in the project and copy the content of the template drawing into it this way. The prerequisite is that the classes used exist in the target project.
How do I insert a reducer and change the nominal size on one side?
Select the reducer in the tool palette and place it directly on the line; it must connect, and the line is then split automatically. Then change the nominal size of the side concerned, e.g. via the annotation or the Properties window of the line segment; the symbol adjusts accordingly. If the reducer in a vertical line points in the wrong direction, change the nominal size directly on the respective line segment.
How do I draw a line that does not visually run through a vessel or filter?
Right-click the line and select Schematic Line Edit > Add Gap. Then click the point before and after the equipment; the line is broken there but remains one continuous line. The gap can be moved later using its grips. Where lines cross, the program creates gaps automatically. Whether a gap or a loop is displayed and how large it is, is defined by the administrator in Project Setup under P&ID DWG Settings in the line settings.
The reducer does not rotate after the nominal size is changed. What am I doing wrong?
The reducer follows the nominal sizes of the connected line sections. Therefore assign the nominal size directly to the line segment (click the line > Properties, or right-click > Assign Tag) and not only via the annotation. For horizontal lines, double-clicking the reducer annotation also works; for vertical lines, assigning it on the segment is more reliable. If it still does not rotate, delete the reducer, decide which nominal size is to be kept, insert it again and then change the nominal size of the affected run.
How do I change the width or height of a vessel afterwards?
Vessels are scaled on insertion (enter the value in the command line, then the rotation angle). Afterwards, select the vessel and change the scale factors for the respective direction in the Properties window. Other symbols such as pumps or filters have a fixed standard size; on insertion, only the position or direction is prompted.
Why can't lines or symbols from a palette be drawn, or why do they appear white?
Tool palettes only refer to symbols in Project Setup. If the palette does not match the project's standard set (e.g. an ISAISA – International Society of Automation US association for automation. Its standard ISA-5.1 specifies symbols and identification letters for instrumentation. Background and sources › or DINDIN – German Institute for Standardization German Institute for Standardization in Berlin: it publishes the German standards (DIN standards) and represents Germany in CEN and ISO. Background and sources › palette in an ISO project) or the symbols are missing in the project, the tools do not work or are displayed as white placeholders. Use the palette group belonging to the project and the matching workspace. Missing symbols must first be brought into Project Setup, e.g. via project comparison.
“Remove Filter” in the Data Manager has no effect – what can you do?
A filter in the Data Manager can only be removed at the node where it was set. To do so, select the node (e.g. the higher level Equipment) and right-click Remove Filter there.
How do I jump from the Data Manager to an object in the drawing?
Select the entire row using the field on the far left (not just a data cell) and activate the Zoom button (magnifying glass) – the program then zooms to the object. Other functions: hide empty columns, filter by selection, Refresh (synchronizes drawing and data). You can drag and drop property values into the drawing as annotations. If the Data Manager has "disappeared", it is often auto-hidden at the edge of the screen.
Why should I draw with grid snap in P&ID, and how do I still hit points outside the grid?
P&ID symbols are matched to a grid; in the ISO templates, snap is set to 2.5 mm. Only then do you reliably hit the connection points of the symbols, and the schematic looks tidy. You can find the settings by right-clicking the snap icon in the status bar under Snap Settings. If you need to snap to a point outside the grid, briefly switch off grid snap with F9F9 Function key in AutoCAD: turns snap mode on or off – the cursor then jumps to the grid points. Background and sources › and use object snap. Move objects that have slipped back onto the grid with MOVE via a base point. Transparency should stay switched off in P&ID, as it slows down large drawings.
Why shouldn't I drag P&ID symbols from the tool palette by drag & drop?
When dragging, the symbol is placed uncontrolled and grid snap is bypassed – it then lies off the grid and lines are later connected at an angle. Instead, click the symbol once in the tool palette; it then hangs on the cursor and you set the insertion point on the grid. In P&ID, always keep grid snap turned on; the template is matched to the symbol sizes.
Plant 3D behaves strangely after a longer break or cannot save – what helps?
After a long idle period or network dropouts, the connection to the project database can be lost. Typical symptoms are messages that a drawing is being used by another session, or functions not responding. Save, close Plant 3D completely (e.g. Alt+F4 and confirm the save prompts), and restart. Recommendation: close Plant 3D before longer breaks. Related support question: “Plant 3D reports “Project locked by another user” although nobody is working in it – what is the cause?” Check the Windows user's rights on the project folder. In the support case, it was due to user rights.
The ribbon or palettes have suddenly moved or disappeared – how do I get them back?
You want your familiar interface back. 1. Use the "Workspace Switching" gear to switch briefly to another workspace and back to the P&ID workspace. 2. If the ribbon is missing entirely, enter RIBBON; if individual tabs or panels are missing, show them again by right-clicking the ribbon. 3. Under Options > Profiles, check whether the correct profile is current, and under Options > Files > Customization Files, whether the main customization file is entered. 4. In the workspace settings, check whether changes are saved automatically; deactivate this and save the desired state under a name of your own. Advantage: accidental changes are not applied permanently.
Gaps appear in P&ID lines at flow arrows – what is the cause?
In AutoCAD Plant 3D 2025 without the update, gaps appear in P&ID lines at flow arrows. Check the version with _ABOUT and install the update; alternatively, deactivate flow arrows in the project configuration.
Can the 255-character limit of the drawing properties be increased, or the input length limited?
Neither can be set: each value holds up to 255 characters, and when you create a drawing property you only define a name and a value. Do you still want long revision texts? Create a separate property for each table cell (e.g. REV_A_INDEX, REV_A_DATUM, REV_A_TEXT), distribute very long texts across two fields in the same cell – or manage revisions as a revision line (Non-Engineering palette): each revision is then its own object in the Data Manager and can be exported to Excel.
How do I export only the data of one drawing or one area from the Data Manager?
In the Data Manager, select the desired node (e.g. the drawing) and use the option “Active nodes only” when exporting. Then only this data is exported to Excel.
P&ID drawings opened in plain AutoCAD show no objects – how do I make them visible?
You want to view or pass on a P&ID drawing in AutoCAD without Plant 3D. There, P&ID objects appear only as proxy graphics; there is no Object Enabler for P&ID. 1. To view: in AutoCAD, set the system variable PROXYSHOWPROXYSHOW AutoCAD system variable: determines how proxy objects – objects from a program that is not currently loaded – are shown: 0 = not, 1 = in full, 2 = as bounding box only. Background and sources › to 1 and run REGENREGEN AutoCAD command: regenerates the display of the drawing in the current viewport. Background and sources ›. 2. To edit in AutoCAD: open the drawing in Plant 3D, right-click it in the Project Manager and select the export to AutoCAD (Export to AutoCAD). 3. Select the location, file name and DWG format and save. Advantage: P&ID components become AutoCAD blocks, lines become lines – the exported file can be opened, edited and plotted in AutoCAD. You continue to edit the original drawing only in Plant 3D.
Why does an off-page connector show a yellow exclamation mark even though the connection works?
Plant 3D compares all properties of the connected lines but shows only some of them under "Show Connection". Align differences in fields that are not shown (e.g. comment, slope, custom fields) in the properties of both lines and save both drawings. If the deviations come from inherited fields, e.g. the drawing area, they are intentional – then you can ignore the message. A Data Manager view of the off-page connectors by line tag and connection number helps with checking: only two arrows may appear per number.
Manual valves and control valves look different – how do I make them consistent?
Put manual valves and control valves on the same layer and align the nominal size label identically for both. The quickest way is to switch the control valve to the layer of the manual valves.
Where does the information in the title block come from, and how do I insert a revision row?
Insert the title block and revision row in the layout from the palette of non-engineering items; drawing is done in model space only. The content comes from Project Setup (project details/project data such as project number, address) and from the drawing properties (right-click the drawing in the Project Manager > Properties, e.g. DWG number, title). You do not enter revisions directly in the title block; instead, insert a revision row for each revision and fill it in via the properties. Revision rows are stored in the database and can be analyzed in the Data Manager.
How do I edit P&ID data (many properties at once) in Excel and import it again?
1. In the Data Manager, select the required node, e.g. Equipment, and click Export – "active node only" produces exactly one table; with child nodes, several sheets are created. 2. Change the values in Excel; do not change the column with the internal IDID – Identifier Unique identifier, e.g. the number under which a record is kept in a database. Background and sources › (PnPID), as it is used for matching. If the sheet is protected: Review > Unprotect Sheet. 3. Save the file and close Excel, otherwise it is locked. 4. In the Data Manager, select the same node and click Import. Changed values are highlighted and can be accepted individually or with "Accept All".
After copying P&ID objects, the transferred fields are empty – what did I do wrong?
First fill in the drawing properties that go into the tag, and do not overwrite the values on the line by hand. The line then passes its values on to valves, inline objects and I&C via the acquisition rule.
How do I keep process-oriented numbering when equipment is added later?
Automatic incrementing does not know the process sequence: it always takes the next higher number, and deleted numbers are not reused either. A proven approach: draw first and leave the tag with a question mark, number later and enter the number manually if needed (with gaps for later additions if necessary). You can change many numbers at once in the Data Manager or via Excel export and import.
Why does the line have a different number before and after inserting a pump?
This is controlled by the symbol's connection type (Class Definitions > Edit Symbol). Pumps are segment group breakers by default: they split the line group, which is why two line numbers are created. Valves are inline objects – the line runs through them. Reducers and spec changes are segment breakers (new segment, same line). Vessels and other equipment are end lines; a line starting there gets a new number. For your own breaker symbols, set the appropriate connection type.
How do I replace an existing line in the P&ID with a different line type without redrawing it?
You want to switch existing lines to a different line type, e.g. after adjusting the project configuration. You do this directly in the drawing via substitution. 1. Click the line in the drawing. 2. Click the substitution grip and select the desired line type in the substitution palette. 3. Check the display and properties of the line. Only objects of the same class are available for selection in the substitution palette. Advantage: you do not have to redraw the line.
When importing from Excel into the Data Manager, the same values are highlighted yellow again with every import – why?
The content is longer than the permitted field length. Plant 3D or P&ID truncates it on import; the Excel list still contains the long text, so every import reports a change. Shorten the text in Excel to the field length.
The signal line does not transfer any values between instrument and line. What is the cause?
Whether properties are acquired via a signal line depends on the configuration and the drawing direction. In the configuration shown, acquisition works when the signal line is drawn from the instrument to the object (line, valve or equipment). Also check that both ends are really connected: when you click the signal line, the end must be shown as round; a plus means open. Update connections that have already been drawn with PLANTREFRESHACQUIREDPROPERTIESPLANTREFRESHACQPROPERTY Command in AutoCAD Plant 3D and AutoCAD P&ID: updates acquired properties – e.g. the line number from an acquisition rule – on objects already drawn. Background and sources ›.
Can I rename a project in AutoCAD Plant 3D afterwards?
You want to change the name of a running project: since version 2026 this is possible in Project Setup. How to proceed: 1. Back up the project. 2. Open Project Setup and expand “General Settings”. 3. Click “Project Details”. 4. Under “General Properties” change the “Project name” field and confirm. Do not use spaces or special characters in the new name either. Note: the Autodesk Help only describes the “Project name” field. It says nothing about the project folder and the file names – so do not rename the project folder by hand. Your advantage: you do not have to create a new project for a new name. Background: wish from the Idea Station, ideas 9264328 (35 votes) and 8454443 (12 votes), as of 07.11.2026. Source: Autodesk Help, What’s New in AutoCAD Plant 3D 2026, “Project Enhancements”. Next step: if your project behaves differently than described, write to support@seitz-ingenieure.de – we will look at it together via remote session.
How do I create custom views in the Data Manager, e.g. nozzles by equipment or order status?
In Project Setup, under the Data Manager configuration, choose "Create View" and define the name and scope (project or drawing). Use "New Level" to build the grouping: first filter the object type (e.g. nozzles), then add further levels by fields such as equipment tag, line tag, manufacturer or a yes/no field "ordered". You will then find the view in the Data Manager under the custom project or drawing views. After changes, reload with the Refresh icon.
How do I get symbols from the configuration, e.g. nozzles, into my tool palette?
First open the target palette. Then go to Project Setup > P&ID DWG Settings > P&ID Class Definitions, select the class (e.g. Engineering Items > Nozzles > desired nozzle) and click "Add to Tool Palette" in the toolbar above the preview. The symbol is added at the end of the currently open palette and can be dragged and dropped to another palette.
A partner is to continue working on our P&ID drawings – what do I hand over?
If the partner continues working with AutoCAD P&ID, pass on the entire project including templates (DWT) and piping specs. If they work only with AutoCAD, export the drawings to AutoCAD via the Project Manager; this preserves, for example, the end connections.
How do I add my own drawing and project properties, e.g. for the title block?
In Project Setup under General Settings > Drawing Properties, first create a category (e.g. "Title block") and the properties below it (e.g. plant section, building); in the Description field you can store an explanatory text. Enter the values for each drawing in the Project Manager: right-click the drawing > Properties. Create project-wide information (e.g. architect, plant designer) in the same way under Project Details. Both types of values can be used in the title block and in tag formats.
How do I make good use of validation, and what do I do with messages that are not errors?
First define in the validation settings what is checked; without a 3D model, deactivate the 3D checks. After "Run Validation", clicking a message zooms to the object. Open the drawing beforehand via the Project Manager, otherwise it is read-only and corrections cannot be saved. After the correction, refresh the node. Set intentional messages (e.g. drawing frames, manhole nozzles, automatically created signal lines) to "Ignore" with a right-click and hide ignored items.
The P&ID commands are missing from the right-click menu, and objects cannot be deleted with Del – how do I get this back?
Set the system variable PICKFIRSTPICKFIRST AutoCAD system variable: determines whether objects can be selected before the command (1) or only after the command is started (0). Background and sources › to 1 (command line: PICKFIRST, 1, Enter). If it is set to 0, objects can only be selected after invoking the command: the shortcut menu then does not show the P&ID functions, tags cannot be assigned, and Del does not delete.
How do I subsequently change a P&ID line to a different medium so that color and linetype change with it?
Select the line, right-click > “Replace” and choose the target line from the palette – style, color and lineweight adapt. The option is missing as long as the line is connected with leader arrows.
How do vessels automatically get a visible nozzle when a line is connected?
In the P&ID class definitions, select the equipment class (e.g. Equipment > Tanks > the vessel you want) and open "Edit Symbol". In the "Default Nozzle" row, select a real nozzle instead of the point nozzle, e.g. the flanged ISO nozzle. Plant 3D then places this nozzle automatically when you connect a line; you can replace it with a different one in the drawing at any time. Tip: the Data Manager can only zoom to nozzles that are visible in the drawing.
The small annotation format window is missing in the Block Editor – where is it?
If the small annotation format window is not visible in the Block Editor, it is usually located on another monitor or one that no longer exists. With the Block Editor open, swap the order of the monitors in the Windows display settings, drag the window to the monitor with AutoCAD, and then restore the original order.
How do I generate lists, e.g. a valve list, with the Report Creator?
1. Start Report Creator via Windows Start > All Apps > AutoCAD Plant 3D folder. 2. Open the project (Project.xml) and choose the scope (entire project or individual folders). 3. Select a report – integrate company-specific report templates via a custom path. 4. Use Edit to adjust the query and layout. Note: Report Creator lists are for output only; to write values back, use export/import in the Data Manager. Related support question: “When do I use the Data Manager Excel export and when do I use Report Creator?” The Data Manager export is intended for data exchange: define columns via the export/import definition; it can be re-imported but has no title block. Report Creator produces print-ready lists with layout, also across classes and with totals – it is not suitable for re-import.
Why can't I correct errors from the validation summary directly in the drawing?
If a drawing is opened via the validation summary, it is read-only. First open the drawing concerned normally via the Project Manager and then click the error in the summary – the program zooms to the location and you can correct it. "Refresh" runs the check again. Messages that are correct from a technical point of view (e.g. nozzles for manholes without a line) can be ignored and hidden.
A reference arrow does not show an inherited property, or only after several restarts – what is the cause?
If an off-page connector does not show an acquired property, or only after several program restarts, a multiple data source may be the cause: the segments of a line group have different values (e.g. operating pressure). Enter the same value in all segments, and it is acquired immediately. The drawing checker (PLANTDWGCHECKERPLANTDWGCHECKER AutoCAD P&ID command: compares the texts in the drawing with the property values in the project database (drawing checker). Background and sources ›) does not fix this case.
How do I force a prompt for an edit history entry when a drawing is closed?
The edit history is kept for each drawing at the bottom of the Project Manager; an entry is created when the drawing is saved and closed. To require users to enter a comment at that point, open Project Setup > Project Details and set the edit history prompt to "When closing project drawings". The next time a drawing is closed, a dialog appears in which you enter e.g. "Drawing created".
Why does a question mark appear in the tag of control valves or instruments?
A question mark in the tag means that a component of the tag format has not yet been filled in. For instruments and control valves, this often includes a field such as Area. Right-click the object, choose Assign Tag and fill in all fields, including Area. Control valves receive an instrument annotation by default; you can later swap the valve body and actuator via "Change Body and Actuator".
Validation reports an open line end at a cap or arrow – how do I fix this?
Check the connection: a round grip at the end of the line means connected, a cross means open. To connect, right-click the line > Schematic Line Edit > Attach to Component. To solve it permanently, go to the class definitions: set end symbols such as caps or connection arrows as line end via "Edit Symbol", and place the connection point at the end of the symbol in the block. Use a separate class for this – settings on, say, the flow arrow apply to all child objects. Changes only take effect in open drawings.
How do I extend the equipment annotation with additional lines, e.g. comment fields?
1. Under Engineering Items > Equipment, add the fields under Properties (e.g., Comment2, Comment3, type String). 2. For the class (e.g., Tanks), select the multi-line annotation in the Annotation area and choose "Edit Block". 3. Click a line, use "Assign Format" to select the field under Class Properties and use target properties; create further lines by copying. 4. Close and save the block. Empty fields appear as a dot – a space as the default value makes them invisible.
How do I back up, name and structure tool palettes for my project?
Right-click the palette bar > Customize Palettes. To rename palettes, click twice slowly (e.g. with a standard-set abbreviation) so it is clear what belongs together. With right-click > Export, back up each palette individually as .xtp – strongly recommended before making changes. Create a new group in an empty white area; collapse all groups first, otherwise a subgroup is created. Create new palettes by right-clicking the tabs > New Palette and fill them by drag and drop. Related support question: “After exporting a tool palette again, folders like “Name (1)” appear and images are missing – what am I doing wrong?” Before exporting again, first delete the palette in AutoCAD and then the old export folder in Explorer. Otherwise the export creates “Name (1)” but still points to the first folder. Put the images in the palette folder. To pass them on, pack the parent folder including subfolders as a ZIP with the date in the name.
An interrupted P&ID line carries its designation on only one segment – how do I merge them?
Edit the line group, select “Add”, click the missing section, and confirm all prompts with Enter. The entire run then belongs to the same line.
Why is there a question mark after some tags – and why is it sometimes missing despite a duplicate number?
The question mark indicates an ambiguous (duplicate) or incomplete tag. It is appended only to the tag itself. If an annotation is built from individual fields instead of the tag, no question mark appears on the drawing even though the number is duplicated. Therefore always also check tags in the Data Manager and reassign faulty tags there or via right-click > Assign Tag.
How do I connect off-page connectors between two P&ID drawings?
Both drawings must be in the same project. Place an off-page connector at each line end. Only connectors whose line already has a line number are offered for connecting. Therefore connect from the side without a number to the side with a number (context menu or plus grip on the connector > Connect). The line number and other values are then transferred, the connector is shown as connected and you can jump directly to the other side.
When does a newly drawn line get a new line number and when not?
If you start in empty space, at a piece of equipment or at a line group breaker (e.g., a pump), a new pipe line group with its own number is created. If you continue drawing from an existing line or an inline valve, only a new segment of the same group is created. You can change the assignment afterwards: right-click the line to be kept > "Edit Line Group" > Add or Remove, and click the relevant sections.
An error message appears when creating a project on the network drive – what can I do?
Common causes are slow network or VPNVPN Virtual Private Network: encrypted connection over the internet into a company network, e.g. from a home office. Background and sources › connections, missing write permissions or cloud-synchronized folders. You can test write permissions by creating a new text file in the target folder. A proven workaround: 1. Create the project locally in a simple folder (e.g. C:\Projekte). 2. Close Plant 3D. 3. Cut (do not copy) the entire project folder in Explorer and paste it on the network drive. 4. In the Project Manager, use "Open" to select the project.xml in the new location.
Can I reuse existing AutoCAD 2D flow diagrams in P&ID?
The drawings can be taken over, but each element must be converted individually into a P&ID object. As a rule, redrawing in P&ID is faster.
The tool palette is marked red in Project Setup. How do I add the project palettes?
Red means that the project's palette group is missing. 1. Open a P&ID drawing. 2. Right-click the title bar of the tool palettes > "Customize Palettes". 3. In the right-hand area, right-click to create a new group and give it a meaningful name. 4. On the left, right-click "Import" to read in the palette files (.xtp) from the template folder one by one and drag them into the new group. 5. Right-click the group to set it as current. Via right-click on the palette > View Options you can set e.g. "Icon with text" for all palettes.
What does the yellow lightning bolt symbol next to a property value mean?
The value is acquired from another object via an acquisition rule, e.g., piping spec, fluid or nominal size from the pipe line group to segments and valves. The source is displayed, sometimes with an English name. Acquisition rules are defined in Project Setup. Note: rules set up later initially apply only to newly placed objects – so define piping specs and rules before the project starts whenever possible.
How can I rotate instrumentation and control (EMSR) symbols (general instruments) in the P&ID?
With the command GENERALINSTRUMENTROTATE, you define whether general instrument symbols may be rotated. After that, they can be rotated as usual.
When swapping symbols in the P&ID, the preview images are missing – what helps?
Close the drawing and delete the file SubstitutionPalettes.xml (back it up first). Then open the drawing and select an object – P&ID recreates the file, and the images appear again.
Why don't colors change after I edited a P&ID symbol, and may I drag it into the palette?
The lines of the original symbols usually have the color "ByBlock"; newly drawn lines get the current setting, often "ByLayer". Do not mix these, otherwise parts react differently to color changes. So do not delete the original line in the Block Editor; modify it instead. An edited block should not simply be dragged and dropped onto the tool palette: the tool then refers to the current drawing and no longer works after purging. New symbols belong in the class definitions via Project Setup.
Which checks should I run before generating lists from the P&ID?
1. Run AUDIT and PURGE in the drawing (including zero-length objects, unused blocks). 2. "Audit Project" in the Project Manager: checks the consistency of the project data and generates a log – only with no open, unsaved drawings, ideally right after a restart. 3. Validation (project, folder or single drawing): engineering check, e.g., open lines, size mismatches, unconnected off-page connectors.
How do I create a list as a PDF with the Report Creator?
Start the Report Creator from the Windows Start menu (Plant 3D program group, or search for "Report"). Under Project, open your project's Project.xml and select the required list under the report configuration, e.g. valve list or equipment list. Use Preview to check the result and Export to create the file. Besides PDF, formats such as Excel, CSVCSV – Comma-separated values Simple text file containing a table: one line per record, columns separated by a delimiter (in German Excel usually a semicolon). Background and sources › or RTFRTF Rich Text Format: text format with simple formatting that almost every word processor opens. Background and sources › are available; for print-ready lists, PDF is the most reliable. Under Settings, you define whether the report templates are stored in the project or in a central folder – this should be consistent across the team.
How do I define a uniform file name format for new P&ID drawings?
In the Project Manager, right-click the project name to open Project Setup and switch to Project Details. Under file name format, click Add and assemble the format from fields, e.g. project number, drawing type and drawing number. For each field you can specify whether it is numeric or a string and how long it may be. When a new drawing is created, the program then prompts for exactly these fields and builds the file name from them.
Can I open a P&ID or Plant 3D project of a newer version in an older version?
No. Projects are migrated when opened in a newer version and are no longer backward compatible afterward. Back up the project before migration and work on the team with the same version.
How do I create a filtered list, e.g. only pumps from one manufacturer, as a PDF report?
Start the Report Creator (e.g. type "Report" in the command line). For project-specific reports, copy the report templates from the Plant 3D program data folder to a reports folder in the project and point the Report Creator to the project. Then create a report based on a template (e.g. equipment list), select only pumps in the query, set a filter (field = value) and click "Test result". In the report layout, add or remove fields and adjust headings; output e.g. as PDF.
How do I export only specific columns from the Data Manager to Excel and bring changes back?
In Project Setup, under the data export/import settings, create a separate definition for the class (e.g. "Equipment Order") and select only the fields you need. In the Data Manager, right-click the class > Export and select this definition. Edit the Excel file and bring it back in via Import. As long as the internal ID column is preserved, the import is safe; alternatively, the tag can serve as the key – in which case tags must not be changed. The column order cannot be freely chosen here.
A project drawing has disappeared or been accidentally overwritten – how do I get an older version back?
You want to restore an earlier version of a drawing. If shadow copies are set up on the drive, you can do this directly in Windows Explorer. 1. Right-click the drawing or the project folder and select Properties > Previous Versions. 2. Select the appropriate version and first copy it to another location to check it. 3. Back up the current version before restoring the file itself; the file name remains unchanged. 4. Then check the drawing in the Project Manager. Advantage: you use existing backups instead of recreating the drawing. Your IT department can clarify whether previous versions are available.
My cloud project does not load – how do I check whether Autodesk is the cause?
At health.autodesk.com you can see the current status of the Autodesk cloud services.
When exporting my P&ID drawings to AutoCAD, end connections are missing – what am I doing wrong?
Export via Project Manager instead of with the single command EXPORTTOAUTOCADEXPORTTOAUTOCAD Command in AutoCAD Plant 3D and AutoCAD P&ID: saves a copy of the drawing in which the plant objects are converted into simple AutoCAD objects – readable without plant software. Background and sources ›. In the support case, all end connections were then present.
By what rule does P&ID break lines at crossings?
Each line class is assigned a priority. If the priorities differ, the line with the higher priority (smaller number, e.g. 1) runs through and the other is broken. If the priorities are equal, the vertical line is broken and the horizontal one runs through. The administrator defines the priority as well as the layer, color and lineweight of the line types in Project Setup under Class Definitions > Lines (e.g. Primary Line Segment). To change a primary line into a secondary line, right-click it and use Replace.
The off-page connector cannot be connected or does not show a drawing number. Why?
To connect, the arrow must be at the end of a line (do not use the line end symbol). Start "Connect To" on the side without a line number; the open arrows with a number are offered. A yellow exclamation mark means differing values: via "Show Connected" you accept them individually or with "Accept All". The drawing number displayed comes from the drawing properties: right-click the drawing in the Project Manager > Properties and enter the DWG number there.
After an Excel import, the annotation shows different values than the line. What happened?
Fields acquired from the line (e.g., the nominal size or piping spec of a valve) are dark gray in the Data Manager. If they are overwritten by an import, they appear light gray – the value is then considered manually changed and no longer follows the line. Validation then reports, e.g., a size or spec mismatch. Clarify which value is correct. If the line value should apply again, restore the acquisition rule for the field. The drawing audit then aligns the annotations in the drawing with the database.
What is the difference between specialty items and hand valves?
Specialty items behave like hand valves and receive their tag in the same way. In the bill of materials, however, they are listed separately and not grouped with the hand valves – use this deliberately for items that are to be listed separately.
When auditing the project, “Exception of type 'Autodesk.ProcessPower.DataLinks.DLException' was thrown” appears – what can I do?
The message comes from Plant 3D's database access. Most common cause: the project is still open on another workstation – often followed by the message that the project is opened by another user. 1. Find out where the project is open and close Plant 3D there completely (closing the drawings alone is not enough). 2. Run the audit again. 3. If the message persists although nobody is working in the project: look for .dwl or .dwl2 files in the project folder – they show on which computer a drawing is still open or Plant 3D has crashed. Start Plant 3D there and exit it normally; do not delete the files by hand. 4. For projects on SQLSQL – Structured Query Language Query language for databases. “SQL Server” is Microsoft's database system; AutoCAD Plant 3D can store its project data there instead of in SQLite files. Background and sources › Server, also check the connection to the server.
Validation reports "unconnected component" for a vessel even though lines are connected.
Some symbols contain predefined connection points at which validation expects a connection. Right-click the object and choose Edit P&ID Object's Block to see where these points are. Connect the lines exactly there. For vessels, fixed connection points usually make little sense; you can delete them in the Block Editor and save the block. Then refresh the parent level of the message in the validation summary, and it disappears.
How do I mark a scope-of-supply boundary in the P&ID and enter the suppliers on the left and right?
Place a scope boundary symbol (segment break) directly on the line – it splits the line into two segments, and the line group is preserved. Then select the left segment and enter the supplier in the Properties palette, and do the same for the right segment. Note: Do not move the symbol along the line, otherwise the segments will not be merged again. Instead, remove it (delete or Ctrl+Z) and place it again. Related support question: “How do I mark a scope boundary in the P&ID, enter the suppliers on the left and right, and mirror the symbol?” Place the scope boundary symbol (segment break) on the line; it splits the line into two segments, and the line group is retained. Then enter the supplier in the properties of each segment. To mirror it, enable “Mirror on insert” in the class definition of the segment break; the symbol is mirrored when you place it next to the line, after which you slide it onto the line. Do not move the symbol along the line – undo it with Ctrl+Z or drag it off the line.
How do I select only the actuator of a control valve, e.g. for the fail-safe position?
Control valves consist of a group (valve body and actuator). The PICKSTYLEPICKSTYLE AutoCAD system variable: determines whether groups are selected as a whole (1) or as individual objects (0). Other values concern hatches. Background and sources › system variable toggles group selection: 0 = individual objects selectable, 1 = group. Set PICKSTYLE to 0, click the actuator and set e.g. the fail-safe position in the Properties window. Swap the actuator or valve type by right-clicking and using "Edit Control Valve" or "Replace". Afterwards set PICKSTYLE back to 1.
Why do my valves with actuators appear in the Data Manager under instruments instead of under hand valves?
This is standard behavior: as soon as an actuator is assigned to a valve, it is treated as a control valve and listed under instrumentation, because it needs I&C properties there. Only valves without an actuator appear as hand valves. Once an actuator assignment has been made, it cannot simply be undone. If you want to list actuated valves under hand valves, you must create custom symbols with an integrated actuator in the hand valve class – so define the rule before the project starts.
I cannot assign a tag number even though it is not used anywhere. What helps?
Usually a database entry of a deleted object still exists. Save and close all drawings of the project. Then, in the Project Manager, right-click the project name and select Validate Project. The function compares drawings and database and removes orphaned entries; you can see the log with F2F2 Function key in AutoCAD: shows and hides the extended text window with the command history – where, e.g., audit reports appear. Background and sources › in the text window or in the log file. If the dialog is marked red or reports unsaved data, restart the program without opening a drawing first. After that, the number can usually be assigned again. Related support question: “A tag cannot be assigned, but the project validation finds no error – what is the next step?” Create a new project based on the existing one (Create project from existing) and copy the drawings into it using “Copy drawing to project”. When opening, the database entries are rebuilt; in the support case, the tag could be assigned again afterward. Create a project backup beforehand.
What does the validation message mean that an annotation is too far from the object?
Validation checks whether annotations are within a defined distance of the associated object so that they can be assigned unambiguously. Often, after a line is split, e.g., by a reducer, the annotation still belongs to another segment. Check via the object which values the annotation shows. If it belongs to the wrong segment, delete it and place it again: right-click the line > Annotate > Line Tag. If it is merely too far away, move it closer and refresh the validation.
The Excel import into the Data Manager aborts with errors – what should I watch out for?
Check the list for special characters; in the support case, a hyphen caused the error. Contents that are too long are truncated to the maximum length and appear yellow again on every import.
How do I adopt the settings from a project template when creating a new project – and why can't a drawing be copied into my new project?
In the Project Manager, select New Project. On the first page of the wizard, enter the name and location and activate "Copy settings from existing project". Use the three dots to select the Project.xml of the template project. Click through the remaining pages with Next, as units, symbol standard etc. come from the template. On the last page, check "Edit additional project settings after creating project" – if Project Setup then opens, the project has been created completely. If an existing drawing cannot be transferred via "Copy Drawing to Project", check the base unit (metric or imperial) of both projects – it is defined when the project is created. In that case, create the target project based on the source project and copy the drawing again.
What is the difference between pipe line group and line segment?
The line group is a database entry that combines a pipe line number from a unique start to a unique end. Properties such as line number and fluid are stored in the group. Line segments are the drawn sections of this group; a new segment is created wherever a parameter changes, e.g., at a reducer. Valves or flanges do not split the line. In the Data Manager, you will find both listed separately under the lines and can check there whether every segment is correctly assigned.
Can you use P&IDs from another Plant project in the 3D model?
Not directly: there is no data exchange between separate projects – the P&ID line list, data transfer and validation work only within one project. You still want to use the P&IDs? Bring the drawings into your project in Project Manager via right-click on “P&ID Drawings” → “Copy Drawing to Project…”. So that classes, tags and piping specs match, the target project should have the same configuration, e.g. because it was created with “Copy settings from existing project”.
Why does my new line get the same number as an existing one, and how do I separate them?
If you start a line at an existing line, it becomes part of the same line group and takes over its number. If you start in empty space or at a piece of equipment, a new group is created. If a branch, e.g., a bypass, should get its own number, right-click the existing line, choose Edit Line Group > Remove, select the section and confirm with Enter. Use Add to combine sections again. Caution: when changing the group, group properties such as the fluid are lost and must be reassigned.
A transfer rule returns the wrong value for individual objects even though it looks correct – what helps?
Remove the acquisition (not the property) at the lower level, close the project configuration and open it again. Repeat this until no foreign acquisition is displayed any more, and then set up the acquisition rule cleanly again at the higher level.
Can I build an additional tag, e.g. a customer tag, from several fields?
Yes, with a calculated property. Under Properties, select “Add”, choose the type “Calculated”, and in the expression editor combine the desired properties using the “Concatenate” operator; place separators in quotation marks between them (e.g. "-"). Optionally set it to read-only. The value is generated automatically without your having to update. Created at the “Engineering Items” level, it is available for all objects in lists – so you can keep your own tag and the customer tag separate. Related support question: “How do I combine several properties (e.g. nominal size, piping spec, medium) in one field for the isometric?” Use the command PLANTDEFINECALCPROPERTIESPLANTDEFINECALCPROPERTIES AutoCAD Plant 3D command: creates calculated properties whose value is composed of other properties, e.g. nominal size, piping spec and fluid in one field. Background and sources › to create a new property (string) and insert the properties by double-clicking; between them use the concatenation symbol “||” with separators in single quotes: Property1 || '-' || Property2. Enter the new property in the Iso.atr and place it in the Iso.dwt.
Why do nozzles or other P&ID objects show question marks in the tag or in the Data Manager?
You want complete tags instead of question marks. A tag is formed from the properties stored in the tag format of the class; if one of them has no value, a question mark appears at that position. 1. Select the object and check in the Properties palette the properties used by the tag format; add missing values. 2. In Project Setup under P&ID DWG Settings > P&ID Class Definitions, check for the class (e.g. Nozzle) under "Tag Format" which format is assigned and which properties it uses. Back up the project before making changes. 3. Alternatively, fill in empty fields in the Data Manager. 4. Then update the tag. Advantage: unambiguous, complete identifications in the drawing and lists.
I scaled P&ID symbols by hand – after opening the project configuration they are back to their old size. Why?
The project configuration determines the size and appearance of symbols and annotations. Set the desired fixed size in the project configuration, and all P&ID elements will be inserted at the correct size.
How do I prevent a value from continuing to be acquired automatically from the pipe line by valves?
You want a property to no longer be acquired automatically from another object. To do this, remove the acquisition rule. Back up the project first. 1. In the Project Manager, open Project Setup. 2. Expand P&ID DWG Settings > P&ID Class Definitions and select the class, e.g. the relevant valve class. 3. Under Properties, in the Acquisition column, click in the field of the property and then on [...]. 4. Select "Remove Acquisition Rule" and close Project Setup with OK. Advantage: you control yourself which values are passed on. Use the same button to add or edit rules.
How do I prevent empty properties (e.g. Supplier) from appearing as dots on the symbol?
In Project Setup, under P&ID DWG Settings > Class Definitions > Engineering Items, enter a space as the default value for the property in question (e.g. Supplier). This applies to all newly drawn objects; the annotation then stays invisible. For existing objects, add the space in the corresponding column via the Data Manager. A space also has the advantage that you can filter for it specifically in bills of materials. Related support question: “Only a dot appears in the annotation of my control valve – why?” A dot stands for a queried property without content – often the annotation queries a property of a manual valve. In the project configuration, open the control valve annotation with “Edit Block” and delete or replace the attribute with the appropriate control valve property. A symbol list property does not work for control valves; create a separate list for this.
How do I specify a uniform file name format with a selection list for new drawings?
In Project Setup under General Settings > File Name Format, you define the components, e.g. project number – drawing type – drawing number. You can enter a fixed project number directly as a separator (adjust it when copying the project!). For a selection list, first create a new list under P&ID Class Definitions > Pipe Line Group on a list field via "Edit List", without assigning it to the field. Then select this list as the field type in the file name format. If it does not appear immediately, close Project Setup and reopen it.
When routing in the 3D model, the line numbers from the P&ID are not offered – what do I need to check in the tag format?
You want to work with the line numbers from the P&ID in the 3D model: Plant 3D only displays them if the tag format of the P&ID line group matches the tag format of the Plant 3D line group; otherwise a message about an inconsistent tag format appears. 1. Back up the project first. 2. Project Setup > P&ID DWG Settings > P&ID Class Definitions > Line Group: view the tag format of the line number. 3. In the Plant 3D Class Definitions, structure the tag format of the line group (P3dLineGroup) identically. 4. Test the transfer. P&ID and 3D line numbers remain separate values; you find deviations via validation. Advantage: line numbers are transferred without retyping.
When is the SQLite database sufficient and when do I need SQL Server?
The option "Single user – local SQLiteSQLite Database in a single file, without its own server. AutoCAD Plant 3D stores project data this way by default. Background and sources › database" stores the database as a file in the project folder. It is suitable for projects where one or two people work at the same time; the project can be moved as a whole and is backed up with the folder's normal data backup. If several people regularly work in the same project at the same time, a multi-user database on SQL Server (e.g., SQL Server Express) should be used. It must be set up by the administrator and backed up separately, and all users need access to the server.
The line number from the P&ID is displayed differently in the 3D model or is not transferred – what is the reason?
You want to transfer line numbers unchanged from the P&ID to the 3D model. Tags are only considered identical if their values match exactly – even an additional space in the delimiter creates a mismatch. 1. Back up the project first. 2. In Project Setup, open the tag format of the line group in P&ID and in Plant 3D (Class Settings > Tag Format). 3. Compare the number and order of the parts as well as the delimiters. Enter delimiters only in the "Delimiter" field between the parts, not within a part. 4. Under Plant 3D DWG Settings > P&ID Object Mapping, check whether all tag components are mapped. This way the line numbers in the P&ID and the 3D model match.
In which files does the project configuration store its settings?
In the project folder: misc.dcf (general settings), ProcessPower.dcf (P&ID), Piping.dcf (Plant 3D), Ortho.dcf, and Iso.dcf. In addition there are IsoConfig.xml and IsoSkeyAcadBlockMap.xml. By replacing, for example, Piping.dcf, an area can be transferred to another project or reset to the default.
A cloud project (Plant 3D Collaboration) reports errors when opening and saving – what helps?
Create a backup of the cloud project, create a new project from it, copy all drawings into it, and upload the project to the cloud again. Make sure that Plant 3D and Desktop Connector or Collaboration are the same version.
How do I turn a pick list into a shared list for P&ID and 3D in AutoCAD Plant 3D 2027 – and back again?
You want to maintain a pick list in only one place: since version 2026 there are shared pick lists that apply to P&ID and 3D classes. If you change the list in one place, it is also changed in the other. Since version 2027 an existing list can be converted. How to proceed: 1. Back up the project. 2. In Project Setup open the “Selection List Property” dialog box of the list. The Autodesk Help lists it under the properties of the root node “P&ID Class Definitions”. 3. Click “Change List Type”. A non-shared list becomes a shared list for P&ID and 3D classes, a shared one becomes non-shared again. The message depends on the current state of the list. 4. If P&ID and 3D already each have a list with the same name, rename one of them or merge both into one shared list. 5. If you work with several projects, align the shared lists in the “Project Compare” dialog box: the “List Settings” table shows the state of each list. There you check the changes from the reference project, accept them and apply them to your project. Your advantage: P&ID and 3D use the same entries, double maintenance is no longer needed. Background: wish from the Idea Station, idea 13966731 (6 votes, as of 07.11.2026). Source: Autodesk Help, What’s New in AutoCAD Plant 3D 2026 (“Project Enhancements”) and 2027 (“Project Management”). Next step: if your project behaves differently than described, write to support@seitz-ingenieure.de – we will look at it together via remote session.
Can I use a transfer rule to copy a value to a different property within the same object?
No. A transfer rule always acts between a line and an object. For combinations within one object, use a calculated property (PLANTDEFINECALCPROPERTIES).
Can I maintain selection lists, e.g. the piping spec or fluid list, via Excel?
Yes. In the P&ID class definitions, open "Edit List" for the field (e.g. in the pipe line group) and export the selected list to Excel. Edit the file, save it and import it at the same place – select "update existing list", not "new list", otherwise a second list is created. Important: the import only adds; rows deleted in Excel are kept and duplicate values are ignored. Afterwards, check the field's default value and set it to the empty entry, otherwise all objects automatically receive a value.
Symbols that I know from another project are missing in my new project – what is the reason?
You want to work with the familiar symbols in the new project. Symbols and classes come from the Project Setup of the project whose settings were copied when the project was created. 1. Check from which template project the project was created and whether the symbols are present there. 2. If they are missing there, create the project again and, in the wizard, activate "Copy settings from existing project" with the correct template project. 3. Transfer drawings that have already been created in the Project Manager by right-clicking the drawing node > "Copy Drawing to Project". Advantage: the new project receives all customized settings of the template project and is compatible with it.
My acquisition rule does not transfer the medium – what is the reason?
Source and target must have the same property type. Nothing is transferred from a selection list to a string (or vice versa). Create both properties identically and then run PLANTREFRESHACQPROPERTY.
At which level do I create custom property fields, and what do I need to watch out for?
As high up as possible, ideally under Engineering Items: fields created there are inherited by all subclasses and appear e.g. in the export of all equipment. Fields on a single class only (say, tanks only) are missing from the export of the parent level. Give the internal property name in English and without spaces or special characters; the display name may be in German. Choose the type (string, numeric, yes/no, selection list, symbol list, acquisition, calculated) carefully – it cannot be changed later.
Do I need separate classes for a symbol in several variants (e.g. labeled left/right)?
No. Store several symbols in the same class. First save the symbol block under a new name in the same folder, and only then change the label or rotation – otherwise you overwrite the original. After inserting, choose the desired variant in the properties under Style > Graphic Style.
Do manual valves, control valves and instrumentation (EMSR) objects need the same tag format?
Compare the tag formats of hand valves, control valves and instrumentation objects: different numbers of digits (e.g. three and five digits) and slightly different formats are possible but should be chosen deliberately so that tags remain consistent.
New P&ID drawings have the wrong layout or no title block. What is the cause?
You want new P&ID drawings to be created with the correct template (DWT). 1. In Project Setup under Paths, check the P&ID drawing template file: copy the path and check in Windows Explorer whether the DWT is located there; select the correct template if necessary. 2. Also check the drawing folder: each folder in the Project Manager can have its own template (DWG Creation Template For Folder) or prompt for one with every new drawing (Prompt For Template). This is defined when the folder is created. 3. Only create folders in the template project once the DWT is in its final location (e.g. server). 4. In the New Drawing dialog you can see at the bottom which template is used. Remove incorrectly created drawings by right-clicking "Remove Drawing from Project" and create them again. Advantage: consistent layouts and title blocks throughout the project.
The project behaves incorrectly after changes to the configuration – what can I do?
1. If an error message appears in Project Setup: close Plant 3D immediately and restart it; do not keep working. 2. Start Plant 3D without a drawing open, right-click the project in the Project Manager > Validate Project and check the log file – any errors found are repaired in the process. 3. In individual drawings, the AutoCAD commands AUDIT and PURGE help. 4. If the problem persists, create a new project based on the faulty one and copy the drawings into it. Related support question: “When saving, Plant 3D reports ‘Database disk image is malformed’ – what should I do?” The project database is corrupted. Create a new project based on the existing one (Create project from existing) and bring over the drawings with “Copy drawing to project”. To rule out the server as the cause, the project can be run locally for a while as a test. Related support question: “During migration to SQL Server, not all drawings are transferred – what can I do?” Check the affected drawings with AUDIT, PURGE and PLANTAUDITPLANTAUDIT Command in AutoCAD Plant 3D and AutoCAD P&ID: checks the drawing against the project database and fixes errors in the synchronisation between the two. Background and sources ›. If that does not help, the safe approach is to create the project anew in SQL Server and bring over the drawings with “Copy drawing to project”. Create a project backup beforehand.
New lines immediately get a piping spec and a fluid – how do I prevent this?
In the template project, check the default values for piping spec and service of the piping group and set them to empty. Otherwise every new line is initially placed with this value.
How do I keep auxiliary lines, e.g. inside a valve block, out of my lists?
Create a separate piping type for these lines in the project configuration. The P&ID functions remain usable; in lists and reports, filter this type out.
How do I make valve numbering start at 01 again for each line?
Include the line number as part of the tag format of the manual valves. Since the tag is then unique per line, numbering can start with 01 again for each line.
How do I make a new piping spec selectable for pipe lines in the P&ID?
In the Project Manager, open Project Setup > P&ID DWG Settings > P&ID Class Definitions and select the pipe line group. There, edit the selection list of the piping spec property (NominalSpec) and add the name of the new piping spec via Add Row. For the link to the 3D model to work, the name must match the piping spec name exactly, and the piping spec must also be copied into the project via the Project Manager.
My custom pipe colors by medium are suddenly gone – why?
If the color settings in Project Setup are changed, custom color assignments (e.g. by medium) are lost.
After moving to SQL Server, my project properties are sorted alphabetically – can I change that?
No. When the configuration files (DCFDCF Project database file of AutoCAD Plant 3D and AutoCAD P&ID, e.g. ProcessPower.dcf (P&ID) and Piping.dcf (3D piping). It contains the project configuration and, in SQLite projects, also the project data. Background and sources ›) are loaded into SQL Server, the properties are sorted alphabetically; this cannot be prevented.
How do I change the number of digits of a tag component (e.g. from 3 to 2 digits) in a running project?
In the tag format, set the expression to the new fixed length. In the drawings, run PLANTREFRESHACQPROPERTIES, export the line groups to Excel in the Data Manager, adjust the values, and import them again. Create a project backup beforehand.
Why can't I create a tag format for a fitting?
The Fittings class does not include a tag by default. The easiest way is to create an element that needs a tag under Hand Valves or Specialty Items. If it is to remain a fitting, create the properties Number, Type and Tag under Piping Fittings and assign a tag format.
I set up an acquisition rule, but existing objects do not show the value. What can I do?
Acquisition rules only apply to objects that are drawn or connected after they have been set up. To apply them to existing objects, enter PLANTREFRESHACQUIREDPROPERTIES on the command line (it can be found via autocomplete, e.g. with "REFRESH") and choose whether the current drawing or the whole project should be updated. All acquired fields are then filled again. Check the result in the Data Manager, e.g. in a custom view that you create under Project Setup > Data Manager.
Why does a vessel prompt for scaling but a pump for the rotation angle?
Each symbol class has its own insertion behavior: whether it is scaled, rotated or mirrored and whether a tag is prompted for. This is stored per project in Project Setup under P&ID DWG Settings > Class Definitions. Select the class there (e.g. Equipment > Filters), click Edit Symbol and set the insertion behavior you want. Since the configuration is stored in the project, you should use a customized project as the template for new projects. Changes to the configuration are the CADCAD – Computer-Aided Design Computer-aided design and drafting. Background and sources › administrator's job.
Why does Plant 3D not transfer the insulation thickness from the P&ID for lines that already exist in the 3D model?
The transfer from P&ID to Plant 3D only takes effect when the line is drawn. If the line already exists in 3D, nothing is added afterward. Export the line group in the P&ID and import it into Plant 3D with the appropriate import setting in the project configuration. First check whether the insulation thickness is set up for transfer in the configuration.
How do I move properties with the same name from the subclasses to the Engineering Items level?
If properties with the same name are to be moved from the subclasses up to the Engineering Items level, work in a new project based on the existing one: note the acquisition rules, delete the properties in the subclasses (note the spelling), do not click Modify in the tag format, create the properties with the same names under Engineering Items and set the acquisitions again. Then copy the drawings into the new project and update the acquisitions with PLANTREFRESHACQPROPERTY.
How do I define a title block that fills itself automatically from project and drawing data?
In the P&ID class definitions, create a class "Title Block" under Non-Engineering Items > Annotation and add a title block via "Add Symbol" (no tag, no scaling). In the block, use "Assign Format" to assign project details and drawing properties, or use AutoCAD fields (e.g. date, file name). Advantage over a title block in the DWT: changes to the block are updated in all project drawings. Create your own project details in Project Setup beforehand. The same title block can also be transferred to the DWT of the ortho drawings.
Can a symbol change depending on a property, e.g. an actuator with a fail-safe position?
Yes, with a field of type "Symbol List". 1. Open the actuator block with "Edit Block", adapt it for each variant and save it under a new name with "Save Block As" (it is stored in ProjectSymbolStyle.dwg). 2. In the class, add the variants from this file with "Add Symbol". 3. Create a symbol list field and assign the matching symbol to each value. In the drawing, you then change the value in the properties. Valve and actuator form a group – with PICKSTYLE 0 you can select the actuator on its own.
Why is a symbol I created in one project not available in other projects?
Symbols and classes always belong to the respective project: the blocks are stored in its ProjectSymbolStyle.dwg, and palettes refer to this file of the current project. For other projects, use the project comparison in Project Setup: select the source project (it must be closed), transfer the blocks first, then the classes and properties, and synchronize. Symbols from other standard sets (e.g. DIN instead of ISO) often have different base sizes and are only partially compatible. Ideally: finish the configuration before projects start.
Empty drawing properties show #### in the title block or revision table – how do I keep the fields empty?
You want clean, empty fields in the title block: In Project Setup, under General Settings > Drawing Properties, enter a single space as the value in the relevant row, and confirm with Apply and OK. In existing drawings, add the space once via Project Manager > right-click the drawing > Properties…; then REGEN. The system variable FIELDDISPLAYFIELDDISPLAY AutoCAD system variable: determines whether fields are shown with a grey background (1) or without (0). The background is never plotted. Background and sources › only hides the gray field background, not the ####.
Sight glasses and similar parts get no tag in the P&ID – how do I change that?
Create such parts in Project Setup under the manual valves (or as a fitting with a tag format). They then receive a tag and appear in the Data Manager and in lists. The class of an existing object does not change if only the block is changed.
How do I restore the original tool palette if it has been overwritten?
Right-click the title bar of the palette and choose Customize Palettes. In the empty white area on the right, right-click to create a new group, e.g. “P&ID ISO Original”. Drag any palette into it and set the group as current by right-clicking. Then, on the left, right-click > Import and import the saved palette files (.xtp) one by one, dragging them into the new group. Afterward, remove the helper palette; change the order by drag and drop. Exporting works the other way around. Related support question: “How do I distribute uniform tool palettes to all workstations?” On the source computer, export the palette group and the palettes (.xtp) under “Customize Palettes” – the image folders of the same name belong with them. On the target computer, first import the palette group, then import a palette and drag it into the group, activate the group, and import the remaining palettes. If icon images are missing, the image folders are not located next to the .xtp files or access rights are missing. Then restart the program.
Why can’t I pass the drawing number on to the line group?
A line group can run across several drawings, so there is no unique drawing number. Instead, create the property on the pipe (line component) or segment and transfer the drawing number there.
When creating a project from the template, a message says the project does not exist – what should I do?
If creating a project from a template reports that the project does not exist and only a few files are created in the project folder, individual P&ID classes or database entries of the template are usually damaged or duplicated. You can narrow this down with the project comparison: first transfer everything except the P&ID classes into a new project, create a test project from it, and then continue comparing group by group. Delete the class you find and purge the block.
Why does a reducer divide the line into segments, but another part does not?
The behavior is defined per symbol in Project Setup (class definition > Edit Symbol). Types include: Inline (sits in the line), Endline (e.g., vessel), Segment Breaker (e.g., reducer – new segment with its own nominal size or piping spec), Line Group Breaker (e.g., pump – new line number) and no connection (annotations). If a component is classified incorrectly, the administrator corrects this; it applies to newly inserted objects.
How do I turn my tested template project into a clean template?
Once you have customized and tested the template project, create a new, clean project from it without test drawings and use that as your template.
How do I compose the line number from drawing properties and a sequential number?
1. Create the values (e.g., plant system, section number) as drawing properties. 2. In the pipe line group, create fields with the same names and the default value "Acquisition" from the drawing properties ("Acquisition" follows later changes, "Initial" writes only once). 3. In the group's tag format, use "Modify" to add the fields and, for each field, choose e.g. a fixed-length number under "Define Expression". 4. Update the tag format of the pipe line segments and annotation blocks in the same way.
How do I increment tags automatically, e.g. pumps from 500 in steps of five?
In the class's tag format, choose “Define Expression” on the number field and create a counter at project or drawing level; set the start value and increment there. A counter on the parent tag format applies to all subclasses – pumps, vessels, etc. would then be numbered up together. For separate number ranges, each object type needs its own tag format with its own counter. Because drawings are rarely created in numerical order, many users assign the numbers afterward by exporting from the Data Manager to Excel and reimporting. Related support question: “How do I set up area-based numbering with automatic counting up?” In Project Setup, open the tag format via “Modify”, increase the number of parts, and choose the property fields. For the line group, clear “Use target properties”. Add missing fields via “Add” (without special characters or spaces). Define the counting up via “Define Expression”, close with OK, and run PLANTREFRESHACQPROPERTY; add missing values in the Data Manager.
How do I keep the option of changing the tag system later?
Set the tag format to the ISO system (type number) and make unneeded properties invisible instead of deleting them. This lets you switch quickly to a different tag system later.
How do I set up my own drawing template (DWT) for P&ID projects?
1. Under Options (right-click in the command line > Options), on the Profiles tab, copy the current profile, rename it and set it current. 2. Under Files > Template Settings, set the template path to a central server folder. 3. Copy the original Plant 3D DWT there, open it and adapt it. 4. In Project Setup, assign the new template under the P&ID DWG Settings. Important: never save a drawing assigned to a project as a DWT – it carries a project ID and causes errors.
I set up a new title block, but new drawings still show the old one – why?
The drawing template (DWT) probably still contains the old block definition, which cannot be purged. Create a new, clean DWT with the new title block and register it in Project Manager or in Project Setup.
A property from the project details has the same value throughout the project – how do I allow different values?
If a property (e.g. the first level of the plant identification) is filled from the project details via an acquisition rule, one value applies throughout the project. If different values are to occur in a project, remove the acquisition rule in the class properties.
The tag of my valves does not arrive from the P&ID in the 3D model – what do I check?
You want to place valves with their P&ID tag in the 3D model. Values are only transferred if the properties are mapped and the tag formats match. 1. Back up the project first. 2. Open Project Setup > Plant 3D DWG Settings > P&ID Object Mapping and check for the valve class which P&ID properties are mapped to which Plant 3D properties. 3. Map every property that occurs in the P&ID tag format – if a mapping is missing, the Plant 3D tag shows a question mark. 4. Compare the tag formats (parts, order, delimiters) in the class settings of P&ID and Plant 3D and align them. This way the tags match, and the synchronization between P&ID and 3D model works.
How does a nozzle automatically acquire the tag of the equipment and of the connected line?
For nozzles, add two fields under Properties (e.g., EquipmentTag, LineTag), default value "Acquisition", source Equipment > Tag or Pipe Line Segments > Line Tag. The segment first acquires its value from the tag of the pipe line group – use the tag, not the line number. New objects receive the values automatically. For existing objects, enter REFRESH in the command line, choose the command to update acquired properties and specify the drawing or project.
Why doesn't automatic valve numbering count back after deletion?
This is intentional: with automatic numbering, a number once assigned is not reused, so that it does not later turn up for a different component in a list that has already been passed on. The counter is maintained in Project Setup in the tag format of the respective class via a project field. An administrator can reset it; numbers already assigned are then skipped until a free one is found. Resetting should only be done deliberately and by agreement.
When creating a drawing, "Value cannot be more than … characters" appears – what can I do?
The message comes from the file name format in Project Setup (Project Details). A maximum length or the type "numeric" is defined there for the field in question. Open the file name format, select the field and adjust the length or type (String instead of numeric); accept with Apply and OK. If the program does not accept the change, it helps to switch the type once, apply, and switch it back. If the behavior persists, check whether the current update for your program version is installed.
I changed the tag format of the line group in an ongoing project – are existing tags adjusted automatically?
No. Existing line groups must be reconfirmed via the Data Manager. Therefore, define the tag format before the start of the project if possible, and use only properties of the line group itself in the line group's tag format.
Layers that I defined for symbols in the project configuration are missing in new drawings – why?
You want new P&ID drawings to contain all project layers right away. Layers and layer colors of new drawings come from the drawing template (DWT) used by the project. 1. In Project Setup, check which P&ID drawing template is specified. 2. Open this DWT itself (not a project drawing), create the required layers with colors and save the template. 3. Create new drawings in the Project Manager via the P&ID drawings node – they are then based on this template. Note: for some classes, the symbol settings override the layer color. This way all new drawings start with a consistent set of layers.
I cannot assign a tag to a strainer in Plant 3D – why?
The strainer class has no tag format. Workaround from support: fill the tag column via Excel import.
An inherited property appears in the subclass as a string instead of a selection list – how do I correct this?
If a property of the parent class appears in a subclass as a string instead of a selection list, the type cannot be changed in the project configuration, only directly in the project database. We will be happy to make this change together with you in a support session – with a project backup beforehand and a check afterwards.
How do I customize an annotation, e.g. on reducers, without changing the original?
In the class (e.g. Inline Assets > Reducer), select the template in the Annotation section and click "Add Annotation": Plant 3D copies the block under a new name. Modify it with "Edit Block" and adjust the fields with "Assign Format". To make the class use it by default, change the Annotation Style at the very bottom of the properties. If you want to be prompted for the position when placing it, select automatic insertion with prompt under "Edit Annotation". Re-place existing annotations.
I cannot replace a valve in the P&ID nominal size and piping spec are grayed out – why?
You want to change values of a valve that are filled via an acquisition rule, e.g. nominal size or piping spec from the line segment or line group. Acquired properties can only be changed once you switch them to override mode in the Properties palette or in the Data Manager. 1. Back up the project before changing the configuration. 2. Open Project Setup > P&ID DWG Settings > P&ID Class Definitions and select the valve class. 3. Under Properties, check the "Acquisition" column: use [...] to add, edit or remove rules. 4. Remove superfluous rules so that each value comes from only one source. This keeps acquisitions unambiguous, and valves can be replaced again.
How do I turn my own AutoCAD block into an intelligent P&ID symbol?
1. Create a block with BLOCKBLOCK AutoCAD command: combines objects under a name with a base point into a block definition that can be inserted as often as required. Background and sources › (objects on layer 0, properties ByBlock, sensible base point) and save the drawing. 2. In the P&ID class definitions, select the appropriate class or create one via right-click > New. 3. Choose "Add Symbols", use [...] to select the drawing containing the block and then the block. 4. Define the layer, scale, rotate/mirror, tag prompt, connection type (equipment: Endline) and automatic nozzle. 5. Choose "Add to Tool Palette". Modifying a similar existing block saves work and keeps the proportions right.
The questions come from our training courses and support sessions – anonymized, without customer or project data. Menu paths refer to current German program versions and may differ by version; the answers do not replace checking in your own project.

Before you go …
Don't miss any training dates, C³ invitations and news on AutoCAD Plant 3D and P&ID.
Our newsletter only arrives when there's something important – concise and with tips from practice.
Technically responsible: A. Seitz, Managing Director of A. Seitz Ingenieur GmbH (plant design, AutoCAD Plant 3D).
Terms, background and sources 30 terms on this page
Brief explanations for reference. They do not replace the standard or code itself.
- R&I – Piping and instrumentation diagram
Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram).
Symbols and drawing rules: DIN EN ISO 10628-1 and -2. Identification letters for instrumentation: DIN EN 62424 or ISA-5.1.
- bar – Unit of pressure
Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”).
- ISO – International Organization for Standardization
International Organization for Standardization in Geneva: it develops standards that apply worldwide (ISO standards).
ISO was founded in 1947. Its members are the national standards bodies; for Germany, this is DIN.
- PDF – Portable Document Format
File format for documents that looks the same on every device and can be printed – e.g. the piping class sheet.
- ZIP – ZIP archive
Compressed archive containing several files in one file. Windows opens it without additional software, e.g. catalog and pipe spec for Plant 3D.
- DWG – AutoCAD drawing format
AutoCAD file format for drawings and 3D models; AutoCAD Plant 3D and AutoCAD P&ID also save in this format.
- DWT – Drawing template
AutoCAD template file (drawing template): new drawings take their layers, styles and settings from it.
- ISA – International Society of Automation
US association for automation. Its standard ISA-5.1 specifies symbols and identification letters for instrumentation.
- DIN – German Institute for Standardization
German Institute for Standardization in Berlin: it publishes the German standards (DIN standards) and represents Germany in CEN and ISO.
DIN was founded in 1917 as the Standards Committee of German Industry. If “DIN EN” or “DIN EN ISO” precedes the number, a European or international standard has been adopted unchanged as a German standard.
- F9
Function key in AutoCAD: turns snap mode on or off – the cursor then jumps to the grid points.
- PROXYSHOW
AutoCAD system variable: determines how proxy objects – objects from a program that is not currently loaded – are shown: 0 = not, 1 = in full, 2 = as bounding box only.
- REGEN
AutoCAD command: regenerates the display of the drawing in the current viewport.
- ID – Identifier
Unique identifier, e.g. the number under which a record is kept in a database.
- PLANTREFRESHACQPROPERTY
Command in AutoCAD Plant 3D and AutoCAD P&ID: updates acquired properties – e.g. the line number from an acquisition rule – on objects already drawn.
- PICKFIRST
AutoCAD system variable: determines whether objects can be selected before the command (1) or only after the command is started (0).
- PLANTDWGCHECKER
AutoCAD P&ID command: compares the texts in the drawing with the property values in the project database (drawing checker).
- VPN
Virtual Private Network: encrypted connection over the internet into a company network, e.g. from a home office.
- CSV – Comma-separated values
Simple text file containing a table: one line per record, columns separated by a delimiter (in German Excel usually a semicolon).
- RTF
Rich Text Format: text format with simple formatting that almost every word processor opens.
- EXPORTTOAUTOCAD
Command in AutoCAD Plant 3D and AutoCAD P&ID: saves a copy of the drawing in which the plant objects are converted into simple AutoCAD objects – readable without plant software.
- SQL – Structured Query Language
Query language for databases. “SQL Server” is Microsoft's database system; AutoCAD Plant 3D can store its project data there instead of in SQLite files.
- PICKSTYLE
AutoCAD system variable: determines whether groups are selected as a whole (1) or as individual objects (0). Other values concern hatches.
- F2
Function key in AutoCAD: shows and hides the extended text window with the command history – where, e.g., audit reports appear.
- PLANTDEFINECALCPROPERTIES
AutoCAD Plant 3D command: creates calculated properties whose value is composed of other properties, e.g. nominal size, piping spec and fluid in one field.
- SQLite
Database in a single file, without its own server. AutoCAD Plant 3D stores project data this way by default.
- PLANTAUDIT
Command in AutoCAD Plant 3D and AutoCAD P&ID: checks the drawing against the project database and fixes errors in the synchronisation between the two.
- DCF
Project database file of AutoCAD Plant 3D and AutoCAD P&ID, e.g. ProcessPower.dcf (P&ID) and Piping.dcf (3D piping). It contains the project configuration and, in SQLite projects, also the project data.
- CAD – Computer-Aided Design
Computer-aided design and drafting.
- FIELDDISPLAY
AutoCAD system variable: determines whether fields are shown with a grey background (1) or without (0). The background is never plotted.
- BLOCK
AutoCAD command: combines objects under a name with a base point into a block definition that can be inserted as often as required.
Sources and origins
- ISO – International Organization for Standardization (for R&I, ISO)
- IEC – International Electrotechnical Commission (for R&I)
- BIPM – International System of Units (SI) (for bar)
- Wikipedia: Portable Document Format (German) (for PDF)
- Wikipedia: ZIP file format (German) (for ZIP)
- Autodesk – DWG (for DWG)
- Autodesk Help (for DWT, DCF)
- ISA – International Society of Automation (for ISA)
- DIN – German Institute for Standardization (for DIN)
- Autodesk Help: Function Key Reference (for F9, F2)
- Autodesk Help: PROXYSHOW (System Variable) (for PROXYSHOW)
- Autodesk Help: REGEN (Command) (for REGEN)
- Wikipedia: Identifier (for ID)
- Autodesk Community: AutoCAD Plant 3D Forum (for PLANTREFRESHACQPROPERTY)
- Autodesk Help: PICKFIRST (System Variable) (for PICKFIRST)
- Autodesk Help: PLANTDWGCHECKER (for PLANTDWGCHECKER)
- Wikipedia: Virtual private network (for VPN)
- Wikipedia: CSV file format (German) (for CSV)
- Wikipedia: Rich Text Format (for RTF)
- Autodesk Help: EXPORTTOAUTOCAD (for EXPORTTOAUTOCAD)
- Microsoft Learn: SQL Server (for SQL)
- Autodesk Help: PICKSTYLE (System Variable) (for PICKSTYLE)
- Autodesk Help: To Set Up a Calculated Property (for PLANTDEFINECALCPROPERTIES)
- SQLite (for SQLite)
- Autodesk Help: PLANTAUDIT (for PLANTAUDIT)
- Wikipedia – Computer-aided design (for CAD)
- Autodesk Help: FIELDDISPLAY (System Variable) (for FIELDDISPLAY)
- Autodesk Help: -BLOCK (Command) (for BLOCK)