Skip to main content
Software und Anwendung für AutoCAD Plant 3D · Autodesk Authorized Training Center · Frankfurt am Main Deutsch · Español · +49 69 9450725-0 · vertrieb@seitz-ingenieure.de

Plant Engineering Infobase · Questions from practice

Questions from practice: Specs & catalogs

90 questions about Specs & catalogs from our training courses and support – with the answer from practice. Free and without login.

Piping specs & catalogs (90)

Does it matter whether I create a new component as an instrument, valve or fitting?

Yes. The component type determines the insertion behavior when drawing and the group in which the component appears in bills of materials and isometrics. A measuring device should therefore be created as an instrument, and a connecting piece as a fitting. Define the type, graphics and end types right at the start, because if you change them later, values already entered must be re-entered. Components for vessel nozzles belong in the nozzle catalog, all others in the pipe, valve or instrument catalogs.

Part type Basics
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How can I quickly see which components and nominal sizes a spec contains?

Right-click the spec in the Project Manager > "Spec Viewer". At the top, only the smallest and largest nominal size is shown for each component type – you cannot see there whether sizes in between are missing. Select a component: the lower area lists every size actually contained individually. The viewer also shows when several components are assigned to one nominal size.

Spec Viewer Basics
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Which specs in the project must I not delete?

Always keep the system specs supplied with the software: Custom Parts (for user-defined components, e.g. via the tool palette), Instrumentation (instruments), Pipe Support (pipe supports) and Placeholder (placeholders, in case a component is not found in a spec). Functions and tool palettes access these directly. You can remove supplied sample specs that you don't use. To add your own specs, right-click "Pipe Specs" in the Project Manager > "Copy Spec to Project".

Spec Editor Basics
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How do I get a new spec into my Plant 3D project?

In the Project Manager, right-click the Pipe Specs node and choose Copy Spec to Project. Select the file with the .pspx extension from your spec folder. Plant 3D copies the .pspx file and the associated .pspc file to the project's Spec Sheets folder. The spec is then available for selection when drawing; you may need to restart Plant 3D once.

Adding a spec to the project Basics
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
When I add a component to the spec, an exclamation mark appears. What does that mean?

Usually a change to the current component in the catalog has not been saved yet. Read the message carefully: save the changes to the component (do not cancel or discard), after which the component can be added to the spec. Save the spec regularly as you work, e.g. before editing the branch table – otherwise some new components may not appear there.

Piping spec Basics
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Which files belong to a catalog and to a spec?

A catalog is a .pcat file; next to it is a folder of the same name with preview images and, if applicable, a DWGDWG – AutoCAD drawing format AutoCAD file format for drawings and 3D models; AutoCAD Plant 3D and AutoCAD P&ID also save in this format. Background and sources › subfolder for block-based parts – the two must always stay together. A spec consists of two files: .pspx (a ZIPZIP – ZIP archive Compressed archive containing several files in one file. Windows opens it without additional software, e.g. catalog and pipe spec for Plant 3D. Background and sources › containing XML, including a reference to the catalogs used) and .pspc (contains a copy of all catalog data used). You always work in the catalog; the spec is assembled from it. Tip: In Windows Explorer, under “View”, show the file name extensions. Related support question: “A part reports faulty catalog data – how do I proceed?” Add the missing data in the part's catalog and then update the catalog data in Spec Editor. Maintain catalogs only via the central location in Spec Editor, never move them in Explorer. Which catalogs a spec uses is stored in the .pspc (column CatalogId, readable with an SQLiteSQLite Database in a single file, without its own server. AutoCAD Plant 3D stores project data this way by default. Background and sources › program).

File structure Basics
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
An instrument is specified in inches on the data sheet – which nominal size do I enter in the catalog?

Assign the inch value to the nominal size via an inch ↔ DNDN – Nominal size (DN) Designation for the size of pipes, fittings and valves (Diameter Nominal). It is roughly the inside diameter in millimeters but is not an exact dimension. Background and sources › mapping table, e.g. ½″ = DN 15, and create the part in the catalog with this DN.

Catalog Basics
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why does Plant 3D insert an eccentric reducer when changing nominal size, or fail to find a route?

If the spec contains both concentric and eccentric reducers, the program uses the component with priority 1. If the eccentric reducer is at the top, routing often cannot resolve the resulting elevation offset. In the part priority for reducers, therefore always put the concentric version first. You can specifically select the eccentric reducer when needed while drawing via Substitute Part.

Reducers Basics
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
On import, the Spec Editor reports that the Excel file is not an exported file – what's wrong?

First check whether the Excel file is still open, and close it. Another common cause is importing in the wrong place: a file exported in the Catalog Editor must also be imported there; a spec export file correspondingly in the Spec Editor. Also make sure that in Excel you only changed values and did not rename any columns or worksheets.

Excel export/import Basics
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I avoid constantly copying the piping spec back and forth between library and project?

You can open the piping spec in the Spec Editor directly from the project's Spec Sheets folder and edit it there. Close all other open piping specs first so that you do not accidentally work in the wrong file – the storage location is shown in the title barbar – Unit of pressure Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”). Background and sources › at the top. Regularly save the current version back to your library and, if in doubt, compare the modification date so that two editing states do not overwrite each other.

Editing a spec Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Why does Plant 3D only insert a placeholder with a yellow exclamation mark at a connection instead of the component?

The placeholder appears when a connection is defined but no matching component is found. Check: 1. Is the connecting part included in the piping spec? 2. Do the end types of the connections in the catalog match? 3. Do both components have the required matching values, e.g. material and nominal size, if these are compared in the connection settings? 4. Are there several entries for the same end type combination? Then the first one is used – remove conflicting combinations.

Placeholders Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How do I edit many sizes of a part at once in the Catalog Editor?

Use the Property Editor (button at the bottom left of the Catalog Editor). It shows all sizes of the selected family as a table, so that you can enter values column by column or paste them with Ctrl+C/Ctrl+V, e.g. an addition to the order text. Save changes beforehand with "Save to Catalog", otherwise the editor still shows old values. Apply them with "Apply". For extensive changes, the Excel export is often faster.

Catalog Editor Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
In the catalog, do I create only the nominal sizes I currently need, or the whole range of the standard?

If possible, create the complete nominal size range of the standard. In our experience, the extra effort for two or three additional nominal sizes is small, and the catalog will then also suit the next project. Only if time is short, limit yourself to the range currently needed.

Catalog Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Same nominal size, different material – do I create a new size or a new part family?

Create a new part family: the material is stored with the part family, not with the individual size. A component made of a different material therefore gets its own family.

Catalog Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I bring a part from another catalog into my own?

In the Spec Editor, additionally open the source catalog via "Open Catalog" (plus icon), find the part on the "Catalog" tab – show the search row via the column filter icon – and copy it with Ctrl+C. Switch to your catalog and paste it with Ctrl+V. Make sure you are on the "Catalog" tab and not the "Spec" tab, as the context menus differ. For variants, use "Duplicate Component" instead of creating a new one.

Parts Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why can't I branch off a line even though there are pipes in the piping spec?

For branches, every piping spec needs a branch table. In the Spec Editor, open the branch table in the piping spec, click "Edit" and add the possible branch types (e.g. tee, nozzle or stub-in). Then select the nominal size combinations of header and branch, and assign the appropriate branch type with a right-click. Without an entry, Plant 3D does not create a connection at that point.

Branch table Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
My decimal value 1,6 becomes 16 after saving. What am I doing wrong?

The correct separator depends on the field: in size variables (e.g. outside diameter, wall thickness, length) enter decimal values with a period, i.e. 1.6. In description texts (e.g. Long Description) write as usual with a comma (German settings). A wrongly placed separator is removed by the Spec Editor on saving without any message – so 1,6 becomes 16. Spot-check the values after saving and after every Excel import. Always select units such as weight from the drop-down list instead of typing them as text.

Size table Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I create a part variant in the catalog without changing the original?

In the Catalog Editor, filter and select the component, then right-click > "Duplicate Component". The copy gets a new, unique long description (family), e.g., with a reference to the pressure rating or purpose. Under "Sizes", adjust the dimensions and purchase text. Important: when changing port data, always edit both sides (port 1 and 2). Accept with "Save to Catalog". Duplicating in the catalog is safer than changing values afterwards only in the piping spec.

Catalog Editor Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
What is the difference between "Save Catalog" and saving in the part?

The button at the bottom right saves only the component currently being edited to the catalog. "Save" at the top or in the File menu writes the entire catalog, including configuration, back from memory. If several people are working on a catalog at the same time, save only individual components; saving the whole catalog would overwrite your colleagues' changes. Only create new properties via the property editor when you are working in the catalog alone.

Saving Advanced
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
Why can't I attach an actuator to the valve I created myself?

When creating a new valve in the Catalog Editor, the selected graphic determines whether an actuator can be attached. Choose a valve graphic of the type valve body (Valve Body); for the variants with a permanently displayed operator, no separate actuator can be attached. Create the actuator as a separate component of the type actuator; in the dimension preview, double-click to see which dimensions, e.g. for a handwheel, need to be entered. Related support question: “Which dimensions from the data sheet go into which fields for a pneumatic actuator with handwheel?” Double-click the actuator to open the dimension image. L is the actuator height, HL the additional height of the handwheel, HD the handwheel diameter; with HA2 = 90° the handwheel points upward. Actuators depend on the actuator type, not on the nominal size. If no existing graphic fits, create a new actuator component instead of copying a wrong one.

Actuated valves Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Where can I get additional catalogs, and can I use them without checking?

The "Content Packs" link at the bottom of the Spec Editor takes you to catalogs and piping specs in the Autodesk App Store, some free, some paid, often in German and English. Close all Autodesk programs before installing. The content usually contains only geometry data and not always complete ordering information; a check for completeness and correctness is not guaranteed. Therefore do not take over parts without checking them; verify dimensions and texts against the manufacturer's or standards documentation.

Content packs Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
I changed components in the catalog, but nothing arrives in the project – what do I need to do?

The piping spec in the project is a copy and knows nothing about later changes. 1. In the Spec Editor, update the spec from the catalog and save it. 2. Replace the spec in the project via the Project Manager: remove it and copy it into the project again – not via Explorer in the Spec Sheets folder. 3. Plant 3D then shows a spec update notification at the bottom right, which you use to update components that have already been placed. Use the Spec Viewer to check whether the component is included.

Updating a spec Advanced
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
What is the best way to test a newly created piping spec?

Copy the piping spec into a test project and draw every component type at least once: a line with elbows, a branch (is a tee placed?), a change in nominal size (concentric reducer?), flanged and threaded connections. Then generate an isometric. If a part is missing its isometric symbol (SKEYSKEY – Symbol key (SKEY) Four-character symbol key for the isometric: the first two characters give the component type, the last two the end connection, e.g. VTFL = gate valve with flanges. Background and sources ›), the line is broken at that point; a rectangle with an asterisk indicates a wrong SKEY with the correct type. Correct errors in the Catalog Editor and then update the piping spec.

Testing a spec Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How do I create weldolets or weld nipples that are placed directly on a pipe?

In the Catalog Editor, do not create the part as a fitting but under the Olet component type, because only then can it be placed on a continuous pipe. Port 1 is the header side; enter the diameter of the pipe it is welded onto there. Port 2 is the outgoing threaded connection. You need a separate size for each header nominal size. After inserting it, check whether the part is oriented the right way round, and otherwise swap the ports.

Olets Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
In which catalog do I create an instrument if there is no dedicated instrument catalog?

Create it in your own valve catalog. The other catalogs in the content folder serve only as templates to copy from and are not edited. Assign inch dimensions to the nominal size via the spec overview (e.g. 1/2 inch = DN 15).

Catalog structure Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why are part blocks missing when I pass my catalog on to colleagues?

Each .pcat file has a subfolder of the same name in which preview images and block-based components are stored. Therefore, only copy a catalog in Windows Explorer together with this folder and only when the Spec Editor is closed – for example when moving to a new content folder. For a new or slimmed-down catalog, it is better to create a new catalog in the Spec Editor based on a working existing one, delete components that are not needed and insert the desired components from other catalogs with Ctrl+C/Ctrl+V. Always pass on catalogs together with the subfolder.

Creating a catalog Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
What does the yellow exclamation mark in the spec editor mean?

Several components of the same type exist for the same nominal size, and no priority has been set. When drawing, Plant 3D always inserts the first component. Click the exclamation mark and set the order: for elbows, the 90° elbow must come first (otherwise, e.g., a 45° elbow is trimmed to other angles), for reducers the concentric one and for tees the equal (non-reducing) tee. Only confirm everything at once after you have checked each entry.

Spec Editor Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How can I build order texts or size descriptions automatically in Excel?

In the exported Excel file, use the CONCATENATE (or CONCAT) function and build the text from the existing columns, e.g. part description, standard, outside diameter, wall thickness and material, separated by spaces or hyphens. In the German version of Excel, the arguments are separated by semicolons, not commas. Drag the formula down over all rows, save the file and import it back into the Catalog Editor.

Order text Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I limit the nominal sizes of a part in the piping spec?

In the Spec Editor, double-click the component or open "Manage Sizes" and deselect all nominal sizes that are not needed. Basic rule: only nominal sizes for which a pipe exists in the piping spec should be available. If there are several pipes per nominal size (e.g., different wall thicknesses), select exactly one here – a piping spec must be unambiguous, otherwise Plant 3D always takes the first one.

Spec Editor Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Why does Plant 3D place a placeholder flange or a placeholder gasket?

Plant 3D did not find a matching part in the active piping spec. The most common cause: pressure rating or facing of flange, gasket and mating flange do not match, or are not entered at all for one part. Check these values in the Catalog Editor for all parts involved, update the piping spec, and replace the placeholders. For verification, you can create your own view in the Data Manager that lists the parts by piping spec and short description – placeholders then stand out immediately. Related support question: “Plant 3D places only a placeholder part (e.g. PH Metric) instead of my bolt set – why?” Check the end type of the bolt set. In the support case, the end type “Undefined_ET” was missing; after adding it in the catalog and updating the piping spec, the bolt set was placed correctly.

Placeholders Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Can I reuse my customized catalogs in a newer Plant 3D version?

In practice, catalogs and specs from recent versions can usually be reused without changes, so you can use the shared content folder for a newer version as well. Even so, keep the older version installed until all Spec Editor functions have been verified in the new version. Do not migrate a running project to a new version in the middle of editing; plan the switch for the start of a project. Related support question: “Can I simply copy catalogs and specs from a different Plant 3D version into my content folder?” Better not without checking. Mixed versions (e.g. a catalog from an older version, a folder from a newer one) led in one support case to no parts being placed anymore. First back up your content folder, work with the same version across the team, and carry over only a few items selectively. Related support question: “How do I migrate my own catalogs with block-based parts to a new Plant 3D version?” Create the CPakCPak Folders in the AutoCAD Plant 3D content directory (e.g. “CPak Common”) containing catalogs and their component files. The program expects these folders unchanged. Background and sources › structure in the new content folder identical to the old one (per catalog, subfolders 32, 64, 200, DWG – with 200 and DWG empty beforehand), extend ContentConfig.xml, then in Spec Editor choose Tools > “Migrate Specs and Catalogs”. The result is located under “Migrated Content”; copy the catalog to the CPak folder, copy the contents of DWG and 200 over afterward, and test with a block-based part.

Version upgrade Advanced
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
Why does the wall thickness show "Varies" even though I entered a value?

Each part has separate values for each connection (Port 1, Port 2). If you have entered a value for only one port, the values differ and "Varies" is displayed. Activate "All Ports" in the dialog, and the value is set for both sides at once. Different values per port are only intended for parts such as reducers.

Size table Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Which description should be maintained in the catalog as the order text?

The purchase text is the long description of the size (Long Description (Size)) – it appears in parts lists and isometrics. It should be complete enough to order without further queries: component type, ordering standard, nominal size or dimensions with wall thickness, pressure rating and material. The long description of the family is only the generic term and is not sufficient for ordering. An inspection certificate belongs in the design details rather than the material code. Purchased or supplied catalogs are only a starting point – always check purchase texts and wall thicknesses.

Order text Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
I moved components to another catalog – why does my piping spec no longer work?

The piping spec refers to the component in the original catalog. First check whether the component exists in the new catalog. Then open the piping spec, remove the old component with Remove from Spec, select the new catalog at the bottom and add the component again with Add to Spec. Save the piping spec and then replace it in the project.

Moving parts Advanced
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
How do I edit catalog data (e.g. wall thicknesses or order texts) in Excel and import it again?

1. In the Catalog Editor, filter for exactly the components you want. 2. Choose “Export” – the current catalog filter is exported, i.e. everything listed below, regardless of the selection; the complete catalog would produce many worksheets. It is best to keep working files in a separate export folder. 3. Edit in Excel, e.g. assemble the order text column (long description, size) with CONCATENATE from description, material, outside diameter and wall thickness. 4. Save and close the Excel file – open files cannot be imported. 5. “Import”: changed components are highlighted in yellow; review the changes, accept them individually or all at once using the arrow buttons, and confirm with “Apply” or OK. Related support question: “How do I change a text in the long description (size) for all nominal sizes at once?” In the Spec Editor, filter for the component, choose “Show all part sizes”, export the current filter to Excel, change the texts and import them again. Then switch back to “Show all part families”.

Excel export Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I correctly create my own catalog or a new piping spec?

In the Spec Editor, always use "Create Catalog from Existing" or create a piping spec from an existing catalog. Only then is the required folder structure with all subdirectories created. Do not copy or rename catalog and spec files in Windows Explorer – finished files may at most be moved. Also, never work in the default catalog; always work in your own copy.

Creating a catalog Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why do threaded parts engage twice as deep as they should?

The engagement length is evaluated on both components. If you enter it on both the female thread (e.g., coupling) and the male thread (e.g., nipple), it is counted twice. Therefore define consistently on which side the engagement length is maintained – either always on the female thread or always on the male thread – and enter 0 on the mating part.

Engagement length Advanced
Parts don't connect? Check end types in the Connection Assistant – free of charge.
Where do the gasket and bolt set at flange connections come from, and why can't I insert them myself?

Gaskets, bolt sets, welds, etc. are connection parts (called "Fasteners" in the Spec Editor). They are created automatically when two end types meet according to the connection settings, and generally cannot be placed manually. For flange connections, the program checks, among other things, whether pressure rating, facing and nominal size match. For this to work, matching gaskets and bolt sets must be included in the piping spec and the corresponding values must be entered for all components involved.

Fasteners Advanced
Parts don't connect? Check end types in the Connection Assistant – free of charge.
Can I simply add new rows for additional sizes in the exported Excel list?

No. Each size has an internal identifier stored in hidden columns, which the import uses to match the rows. New rows without an identifier find no counterpart, and copied rows would overwrite the original row. Therefore create additional sizes in the Catalog Editor first (e.g. duplicate the size and save), then export and enter the values in Excel.

Excel export/import Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Does a piping spec in the project work without access to the content folder?

Largely yes: when copied into the project, the piping spec is placed in the project folder "Spec Sheets", and the .pspc contains all catalog data. This allows you to draw without the content folder being accessible. The exception is block-based parts (e.g. valves with stored DWG geometry): these refer to the DWG subfolder in the content folder. To administer the piping spec, on the other hand, you always need the associated catalogs.

Content folder Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I set up the branch table so that tees are inserted at branches instead of pipe-to-pipe?

1. In the Spec Editor, open the Branch Table tab and edit the legend: add branch types, e.g., tee, reducing tee or tee plus reducer. 2. Select the cells in the table (multiple selection with Ctrl or Shift) and assign the desired branch type via right-click. Only combinations for which matching components exist in the piping spec are offered. Additional variants marked as permitted serve only as documentation in the export and do not affect drawing.

Branch table Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Why are two bolt sets placed for wafer valves or spectacle blinds?

The component has the wrong end code. Wafer-type components (e.g., wafer butterfly valves, orifice plates, spectacle blinds) must have the end code WFWF – Wafer type (between flanges) End code of a component connection in AutoCAD Plant 3D: wafer type, e.g. for orifice plates or butterfly valves between two flanges. Plant 3D then places only one through-bolt set. Background and sources › at both ports, not FLFL – Flange End code of a component connection in AutoCAD Plant 3D: flange. Plant 3D adds a mating flange with gasket and bolts. Background and sources ›. Plant 3D then places only one continuous bolt set. To change it in the Catalog Editor: select the component > connection port properties > set the end code to WF, use the arrow to switch to the other side and select WF there as well. Choose "Save to Catalog" and update the piping spec.

End codes Advanced
Parts don't connect? Check end types in the Connection Assistant – free of charge.
How do I turn a manufacturer's STEP model into a catalog part?

1. Import the STEPSTEP – Standard for the Exchange of Product model data Vendor-neutral 3D exchange format for parts (ISO 10303), e.g. for equipment from the manufacturer. Background and sources › model into a DWG, explode blocks until only solids remain and remove unnecessary details. 2. Place the base point at the future connection and create a uniquely named block. 3. Use the PLANTPARTCONVERTPLANTPARTCONVERT AutoCAD Plant 3D command: turns an AutoCAD block into a piping component by adding connections (ports). Background and sources › command to define the ports (point, direction, accept, add, exit). 4. In the Catalog Editor, create a new component with block graphics and use "Select block from model" to choose the DWG containing the block. The DWG must remain permanently accessible.

Block-based parts Advanced
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
After updating the piping spec, properties such as the material are missing – why?

When updating from the catalog, the component data in the piping spec is replaced by the catalog values. Values that you entered only in the piping spec via property override can be lost in the process. If connections depend on these values (e.g., material matching), placeholders are inserted afterwards. Therefore enter values you need permanently directly in the catalog whenever possible, and check the properties in the Spec Editor after every update.

Updating a spec Advanced
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
How do I get connection points placed automatically in long pipes?

For the pipe in the catalog, enter a fixed length instead of a variable length, e.g. 6000 mm. Plant 3D then automatically divides the line into sections of this length. Which connection is placed between them depends on the end type of the pipe: a weld for butt-weld ends, and the appropriate connecting part, e.g. a coupling, for other end types.

Pipe length Advanced
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
No component images are displayed in the Catalog Editor – why?

Often the program version and the content folder do not match. Check which version the content comes from, and transfer the catalogs to the content folder of your version.

Content folder Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
A threaded connection between two parts is not established – what could be the cause?

In the project configuration, check the connection setting of the threaded connection, especially the option for British and metric connections, as well as the connection information of both components (metric/British). In the support case, this option was the cause.

Connection settings Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
A flange from the piping spec does not appear in the selection – why?

If a flange added to the piping spec does not appear in the selection, check its part class: if it is defined as a stub end, it counts as a connection part and cannot be placed on its own. Create the part as a flange; then it can be placed.

Flange Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
Plant 3D calculates no bolt length or a wrong one – what is the reason?

First check whether a flange thickness is entered on the flange or valve and on the bolt set – without it, no length is calculated. Plant calculates: bolt set length − 2 × bolt set flange thickness + flange thickness of flange 1 + flange thickness of flange 2, and rounds up to the next value of the bolt assignment standard; if no standard is stored in the bolt set under “By Standard”, it rounds up to full 10 mm. For loose flanges, the collar or flared edge counts toward the flange thickness; for wafer-type valves (e.g. butterfly valves), the face-to-face length is added – enter that length in the “Flange thickness” field. Valves with tapped blind holes receive the thread engagement depth instead of a flange thickness; those are rounded down. In one further case, it helped to create all connections individually in the connection settings instead of combined.

Fasteners Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
Should each user use their own catalog folder?

No. By default, the installation creates a local content folder with several content packs (e.g. a shared catalog for nozzles, supports, instruments and placeholders, as well as standards-based catalogs). In production use, a shared network folder is recommended so that all users work with the same catalogs and piping specs and nobody has to maintain their own set separately. After changing the content path, restart the Spec Editor, as it reads the configuration at startup.

Content Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why can't I assign a tag to a valve in Plant 3D?

This is usually due to the selected class: not every class has a Tag property. Select a class with a tag or add one in the configuration.

Tag Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
After the version change, my piping specs still access the old content folder – how do I switch them to the new catalogs?

The catalog path is fixed in every piping spec. If the old content folder is to be kept, rename it (e.g. with "_alt") instead of migrating the specs. Then open each spec in the Spec Editor: Plant 3D reports the missing catalog and asks for the new location. Switch to the new catalog folder and append ".pcat" to the catalog name in the File name field – without ".pcat" only the folder of the same name opens. Repeat this for every other catalog of the spec and save. Ideally, switch the specs over once in the template and then copy them into the projects.

Version change Administration
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
How do you create a valve from another manufacturer that looks similar to an existing one?

You do not want to rebuild a similar part from scratch: 1. In the Catalog Editor of your own catalog (never the original catalog), select the existing part family and click “Duplicate component”, then give it a new name. 2. Adjust standards and “Long Description (Family)”. 3. For each nominal size, change “Long Description (Size)” and differing dimensions – with many sizes, export to Excel, edit and re-import. 4. Save with “Save to catalog” and add the part to the piping spec.

Catalog Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I create a component for the piping spec from a solid (e.g. STEP or a manufacturer model)?

1. Insert the solid at 0,0,0 and align it with the X axis. 2. Use BLOCKBLOCK AutoCAD command: combines objects under a name with a base point into a block definition that can be inserted as often as required. Background and sources › to create a block with base point 0,0,0 and save the drawing. 3. Convert it into a Plant part with the function for block-based parts and set the center point and direction at each connection; finish the function with "Exit", not with Enter. 4. In the Spec Editor, create a component with custom graphics and assign the appropriate block to each nominal size. For many sizes, parametric scripts are more efficient.

Parts Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I take only certain sizes from the catalog into the piping spec in AutoCAD Plant 3D 2027.1 and set properties at the same time?

You want to fill a piping spec faster and without rework: since version 2027.1 the Catalog Browser in the Spec Editor has a size filter and property overrides. Both can only be set when the “Spec” tab is active. How to proceed: 1. Open the piping spec in the Spec Editor and select the catalog in the Catalog Browser. 2. Next to “Spec size filter” click “Set”. In the “Size Filter” dialog box you set the smallest and the largest size, the size range for reducers and the sizes you want to exclude. 3. Next to “Spec overrides” click “Set”. In the “Property Overrides” dialog box select or type a property, enter the value and add further rows with “Add Row”; with “Remove Row” you take a row out again. 4. Insert the parts with “Add to Spec”. Only the sizes shown after the filter are taken over. The overrides replace the matching values in the piping spec. Note: the filter only applies to the active catalog and is reset when you change the catalog. You see the active range next to “Spec size filter”. Your advantage: you delete and change far fewer rows by hand. Background: with this Autodesk has implemented wishes from the Idea Station, e.g. idea 11583964 (108 votes) and idea 13702160 (27 votes), as of 07.11.2026. Source: Autodesk Help, What’s New in AutoCAD Plant 3D 2027, section 2027.1 “Spec Editor Enhancements”. Next step: if your project behaves differently than described, write to support@seitz-ingenieure.de – we will look at it together via remote session.

Spec Editor Administration
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
I created a new end code, but the connection does not work for my colleagues. Why?

Newly defined end types (end codes) are stored locally in the program folder of each computer, whereas the join settings are stored in the project. Every user must therefore create the end codes identically on their own computer. Agree on new end codes within the team and document the names. If they are missing, the joins are not created or messages such as “Parts cannot be joined” appear. Related support question: “Where are my custom end codes (EndCodesConfig.xml) stored?” User-specific under %AppData%\Autodesk\Autodesk AutoCAD Plant 3D \\deu\Support. This is why custom end codes are missing on workstations to which the file was not distributed.

End types Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
How do I create a part in the catalog that does not exist yet?

In the Catalog Editor, choose "Create Component". 1. Specify whether it is a parametric component or an AutoCAD graphic (block). 2. Select the component type (e.g., flange, valve, fitting) and the matching base shape. 3. Enter the dimensions for each nominal size: with 0, the dimension is calculated automatically; with -1, the element is not displayed. 4. For each port, define the end code, pressure rating and facing, and assign the long description/purchase text. Then add it to the piping spec and use it in the test project – always try out new components before using them in production.

New component Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Can I edit the piping spec file (.pspc) directly?

A piping spec consists of the .pspx (a compressed file containing, among other things, the component list, branch table and priorities) and the .pspc, an SQLite database with a complete copy of the component data from the catalog. That is why a component in the piping spec can have different values than in the catalog. Technically, the database can be opened, but because of the internal links, an incorrect entry can quickly destroy the piping spec. Therefore always make changes via the Spec Editor.

Spec file Administration
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How do I take individual parts, e.g. a weld neck flange, from a downloaded catalog into my own?

Additionally open the downloaded catalog in the Spec Editor and show the column filter. Filter by short description, pressure rating and facing, select the component, copy it with Ctrl+C and paste it with Ctrl+V on the Catalog tab of your own catalog (the Spec tab only offers “Add to spec”). Remove nominal sizes you do not need, add missing ones by duplicating, and check the end type and pipe outside diameter.

Parts Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
The manufacturer gives no pressure rating for a component – what do I enter in the catalog?

Do not estimate: A wrong entry is worse than a missing one. Leave the field empty and clarify the pressure rating with the supplier. Keep in mind, however: without a pressure rating, Plant 3D cannot form a flange–gasket–bolt set connection, because pressure rating, nominal size, and facing must match for that. Therefore, add the component to a production piping spec only after this has been clarified.

Properties Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
When inserting a component, Plant 3D reports that it cannot be created with the parameters – why?

The catalog or spec is missing dimensions for this size. Add the missing values in the Catalog Editor, update the spec in the project, and place the part again.

Catalog Editor Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
When inserting a custom part, “The path is not of a legal form” appears – what should I check?

If System.ArgumentException: The path is not of a legal form appears when inserting a custom part, check whether the content folder is correctly assigned and complete, and whether the piping specs of the custom parts exist in the project.

Content Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I name piping specs sensibly, and how do I pass a piping spec on for review?

A naming scheme made up of pressure rating, material, sequential number and, if applicable, flange or gasket type has proven effective. Material, pressure rating, temperature range and medium belong in the description of the piping spec; they also appear in the Excel export. For review, export only “Spec sheet and branch table”; for complete documentation, use the full export with all components.

Piping spec Administration
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How do you bring a few self-made block parts into a piping spec?

1. Never change the original catalog: create a copy via File → New → “Create catalog from existing…”. 2. First add connection ports to the block with PLANTPARTCONVERT and save it. 3. In the Catalog Editor choose “Create new component”, select the custom block-based AutoCAD DWG graphic under Graphics, and add port values and the long description. 4. Under “Sizes”, assign the matching block for each nominal size via “Select model…”. 5. “Save to catalog” and add the component to the piping spec.

Catalog Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Can a PLM system read the project data from P&ID or Plant 3D?

Officially, Autodesk supports only Vault and Autodesk Docs/BIM 360.BIM – Building Information Modeling Planning, building and operating with a digital model that contains not only the geometry but also the properties of the components. Background and sources › In SQLite projects, the DCFDCF Project database file of AutoCAD Plant 3D and AutoCAD P&ID, e.g. ProcessPower.dcf (P&ID) and Piping.dcf (3D piping). It contains the project configuration and, in SQLite projects, also the project data. Background and sources › files are databases and can be read if the PLMPLM – Product Lifecycle Management Management of all data of a product over its entire life – from development through manufacturing and operation to decommissioning. A PLM system is the software for this. Background and sources › system can query databases; in SQLSQL – Structured Query Language Query language for databases. “SQL Server” is Microsoft's database system; AutoCAD Plant 3D can store its project data there instead of in SQLite files. Background and sources › Server projects, the DCF contains only the connection to the database. Changing the data via the PLM system is not supported.

Project data Administration
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
Valves only show their connection points when placed, but the geometry is correct in the Spec Editor – what can I do?

You want to see your valves completely in the model again: usually the storage location of the block-based components does not match the catalog. This happens, for example, with a downloaded catalog that lacks the subfolder of the same name. Plant 3D then stores additional block-based components in a separate folder instead of next to the catalog. If old content folders also exist, the paths are no longer unambiguous. How to proceed: 1. Back up the catalog, piping spec and project. 2. Move the folder with the block-based components to the catalog – it belongs next to the .pcat file as a folder of the same name. 3. Rename old content folders (e.g. with “_alt”) instead of deleting them. That leaves only one valid path. 4. Open the piping spec in the Spec Editor and explicitly link it to the correct catalog: when opening, Plant 3D asks for the missing catalog; select the catalog in the new folder and append “.pcat” in the File name field. Save the piping spec and update it in the project. 5. Place a valve in a new drawing as a test. 6. Do not repair the affected drawing: select the pipelines, copy them with Ctrl+Shift+C (Copy with Base Point) and paste them into a new drawing. Your benefit: the piping spec and components work again without redrawing the model.

Catalog Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
My modified Excel list is not recognized when importing into the catalog – what is wrong?

Import at the same level where you exported: gaskets into gaskets, valves into valves – not at the parent level of the piping system. In addition, the structure of the exported file must not be changed.

Excel export/import Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Plant 3D places two bolt sets on a wafer butterfly valve – how do I correct this?

If Plant 3D places two bolt sets on a wafer butterfly valve, remove the entry in the “Bolt Set” joint component in the connection settings. Plant 3D places the long bolt set for wafer valves automatically as soon as the end type is defined as “Wafer”.

Bolt set Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
How do I specify whether a tee, a reducing tee or a nozzle is placed at branches?

In the Spec Editor, open the branch table. 1. Use "Edit Legend" to create the permitted branch types, e.g., pipe-on-pipe/nozzle, equal tee, reducing tee or tee with reducer. 2. In the matrix of header and branch sizes, select the cells (Ctrl + left mouse button for multiple selection) and assign the appropriate branch type. Plant 3D only uses components contained in the piping spec; if one is missing, it points this out. The basis should be the branch specifications of your piping spec definition.

Branch table Administration
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
How do I specify which connecting part is inserted when two end types meet?

In the Project Manager, open Project Setup > Plant 3D DWG Settings > Join Settings. The upper area shows which end types may be joined directly to each other; in the lower area you define joins in which a part is inserted (e.g. nipple or coupling). Assign a join name without special characters or spaces, select the two end types and the part to be inserted, and specify which values must match (e.g. nominal size, material). The part must also exist in the piping spec. Related support question: “How can I make a nipple be placed automatically on a coupling (and vice versa)?” In Project Setup > Plant 3D DWG Settings > Join Settings, remove “PLPL – plain end End code of a component connection in AutoCAD Plant 3D: plain end, e.g. of a pipe. Background and sources ›” from the threaded join under the simple joins; under the multiple joins, change the auto threaded join to “THDMTHDM – Male thread End code of a component connection in AutoCAD Plant 3D: male thread. Background and sources › / PL” and use “…” to select only short description and nominal size as properties. Also create a “THDFTHDF – Female thread End code of a component connection in AutoCAD Plant 3D: female thread. Background and sources › / PL” join in the same way. The parts need a matching short description for this.

Connection settings Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
How do I structure my catalogs sensibly so that the Spec Editor stays fast?

A split by material and function has proven effective, e.g., pipes/fittings per material, valves, instruments and a separate gasket catalog, since gaskets are used across materials. Delete unneeded sizes and standards in copies. The standard end codes are predefined in the program; you can add your own. An emptied catalog initially keeps its file size; after a backup, this can be reduced with an SQLite tool using the VACUUM function. Never work in the original catalogs, always in your own copies.

Catalog structure Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Can a long description style (LDS) output values of the second connection?

A long description style (LDS) only accesses the values of the first port; wall thickness or outside diameter of the second port cannot be included. An entry such as S2S1, S2 First and second connection (port 1, port 2) of a component in AutoCAD Plant 3D, e.g. in the catalog and in the isometric configuration. Background and sources ›.WallThickness in the LDS file causes the Spec Editor to crash. For inline components, only the nominal size of the first port counts.

Long description Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I set up a custom flange connection, e.g. for two different mating flanges (tongue/groove)?

1. With a drawing open, go to Project Setup > Plant 3D DWG Settings > Connection Settings and use "Add" to define two new end types (end codes) with "Flange" checked; use letters only for the names. 2. Create the connection of the two end codes with gasket and bolt set and select the matching properties (nominal size, pressure rating, facing). 3. Define that the mating flange is placed whenever a pipe is encountered. 4. Enter the end codes for the flanges in the Spec Editor.

End types Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
Why are new rows that I add to the exported Excel list not imported?

Each size has an internal identifier in a hidden column of the Excel file. The import uses this identifier to match the rows. If you copy a row, the identifier is duplicated – the last one imported overwrites the first. New identifiers cannot be created in Excel. Excel is therefore only suitable for changing existing entries. Create new sizes or variants in the Spec Editor first (e.g. with "Duplicate Component"), export again and do the fine-tuning in Excel.

Excel export Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
No welds appear on bent pipes – what is the cause?

If no welds appear on bent pipes, check the end type: the pipe needs PL; BVBV – Butt weld end End code of a component connection in AutoCAD Plant 3D: weld end (butt weld). Where BV meets BV or a plain end, Plant 3D places a weld. Background and sources › is intended for fittings. If BV meets PL, no connection component is defined in the connection settings.

End codes Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
My block-based component places the wrong block at one nominal size – what is wrong?

Block-based components are sensitive to block names and nested blocks. Check whether the block name and content match. The safe approach: create one clean block per size from a 3D solid (inner blocks exploded), convert it with PLANTPARTCONVERT, and reassign it in the Spec Editor.

Block-based components Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
A pipe standard includes several series with different outside diameters – how do I represent this in the catalog?

Duplicate an existing pipe component and create a separate part family for each series, because the outside diameters differ. Identify the series in the designation. If possible, create the entire nominal size range of the standard – a few extra nominal sizes cost hardly any time. Fittings and flanges must use the same series, otherwise the connections do not match.

Catalog structure Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do we set up a shared catalog folder (content folder) so that several colleagues work with the same catalogs?

1. Start the Spec Editor via right-click "Run as administrator". 2. Under Tools > Shared Content Folder, click the three dots and select a folder on the network drive to which everyone has write access. 3. Only the first user checks the box to copy the local content so that their content is transferred to the network folder; all other users select the same folder without the check mark – otherwise the content would be overwritten. The setting applies per computer, not per user, and must be made on every workstation with administrator rights. Do not delete or rename the existing CPak folders; the program expects them.

Shared content Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I add an additional property to a catalog, e.g. an English description?

In the catalog, open the property editor ("Manage Properties"), enter the name without spaces or special characters and choose whether the property applies at part family or part size level. Be sure to select "All Parts" instead of only the current part, otherwise the field will be missing for other parts. Apply with "Add" and "Apply". A deleted property name may not be reusable later – so plan the names in advance.

Properties Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How do I bring a modified piping spec into an existing project and existing drawings?

Always bring the piping spec into the project via the Project Manager: remove the spec there and insert it again using "Copy Spec to Project". Do not copy or overwrite files in the "Spec Sheets" project folder in Windows Explorer – such copies often do not arrive in the project. Then open the drawing: a spec update notification appears in the status bar. Right-click to start the check and update the components. Afterwards, check in the properties of a component whether the new values have been applied; if in doubt, place the component again.

Updating a spec Administration
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
I only have the piping spec left, but no catalog – can I recover the catalog?

Yes. In the Spec Editor, export the piping spec in Excel format for the Pipe Catalog Generator, start the Pipe Catalog Generator, open and validate the file, and save the result as a new catalog (.pcat) or add it to an existing one. This only works for script-based parts, not for block-based ones. Identical parts from several piping specs are created twice. Since the associated catalog subfolder is not created in the process, copy the parts into a properly created catalog afterwards.

Restoring a catalog Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why does “mm” appear after new nominal sizes, and how do I fix that?

“mm” means: Plant 3D does not know the nominal size. Add it in the NominalDiameterMap.csv (Size IDID – Identifier Unique identifier, e.g. the number under which a record is kept in a database. Background and sources › sequential, value, unit, display, conversion, alternative display); for the reverse direction (e.g. inch → mm), add a separate row. Deploy the modified file on all Plant 3D workstations.

Size table Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Custom parts no longer work reliably – is this due to different program versions?

If different program versions (e.g. 2022 and 2026) access the same content folder, custom components no longer work reliably. Work with one version, back up the content as a ZIP after installation, and copy in only the PCATPCAT AutoCAD Plant 3D catalog file with all components of a catalog, their sizes and properties. Technically it is an SQLite database. Background and sources › files you need together with their associated folders.

Content Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
How does Plant 3D decide which mating flanges, gaskets and bolt sets are placed automatically?

The basis is the end codes of the component ports (e.g., FL = flange, BV = butt weld end, PL = plain end, THDF/THDM = female/male thread). Which codes exist is defined in the program; what happens when they meet is defined per project in Project Setup under Plant 3D DWG Settings > Connection Settings. There it is specified, for example: if FL meets FL, a gasket and bolt set are inserted, provided nominal size, pressure rating and facing match; if FL meets a weld or plain end, a mating flange is placed.

End codes Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
After updating the piping spec, one component is replaced by another – why?

Presumably two parts have the same internal ID (PnPID), e.g. after sloppy duplication in the catalog. Duplicate the part again in the Catalog Editor and save; this creates a new component with its own ID. Then update the piping spec.

Updating a spec Administration
Problem still there? We check your project together via remote session – for new companies the first 45 minutes are free.
What determines what happens at a connection – the geometry or the end type?

What happens at a connection is determined solely by the letters of the end type, not by the appearance or the geometry values of the 3D model. Examples: BV butt weld, THDM male thread, THDF female thread, PPLPPL – Plastic weld End code of a component connection in AutoCAD Plant 3D: plastic weld. Background and sources › plastic weld, PSWPSW – Plastic socket End code of a component connection in AutoCAD Plant 3D: plastic socket. Background and sources › plastic socket; FL always creates a mating flange, BV a weld. Therefore, check all connections of every component.

End codes Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
Where can I get better catalogs than the ones supplied, and what do I need to watch out for when installing them?

Additional content packs (e.g. German-language pipe and fitting catalogs or steel construction catalogs) are available in the App Store, accessible via the Plant 3D start page; many of them are free. Downloading works without administrator rights, but installing into the Shared Content Folder does not. Back up your existing catalogs before installing, as an installer can overwrite catalogs of the same name. Check downloaded content before using it, as it may contain errors or incomplete information.

Additional catalogs Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.
Why can't I assign an actuator to my valve?

Actuators can only be assigned to components of type ValveBody, not Valve. Create valves that are to receive an actuator as ValveBody.

Actuated valves Administration
New piping spec needed? Preliminary sizing of the piping spec in the Piping Spec Calculator – with a free customer account; preliminary sizing, not a piping design.
Plant 3D places the wrong bolt sets at flange connections – how do I define which one is used?

You want the desired bolt set to be placed at flange connections. 1. Open the piping spec in the Spec Editor and check the bolt sets it contains for each nominal size; remove those not needed so that, if possible, only one suitable set remains per size. 2. If the spec still contains several parts of the same group for one size, the spec sheet shows a yellow warning symbol in the Part Use Priority column. 3. Click it, use the arrows in the dialog to define the order and mark the conflict as resolved (green circle). 4. Save the spec, update it in the project and check it in a test model. This gives you an unambiguous, traceable selection.

Fasteners Administration
Parts don't connect? Check end types in the Connection Assistant – free of charge.
In the Catalog Editor, the wall thickness shows “varies” even though I entered the same value everywhere – why?

Many values exist per connection, e.g. wall thickness 1 and wall thickness 2. If you have filled in only the first connection, the values differ and the editor shows “varies”. In the input form, enable “All connections” so the value applies to both sides – or fill in both columns. For reducers, deliberately enter different values on the left and right.

Catalog Editor Administration
Catalog faulty or incomplete? Check the catalog in the Catalog Checker – we check the first catalog per company free of charge.

The questions come from our training courses and support sessions – anonymized, without customer or project data. Menu paths refer to current German program versions and may differ by version; the answers do not replace checking in your own project.

Your question is not included? Write to us – or resolve it directly via remote support or in a training course.

Technically responsible: A. Seitz, Managing Director of A. Seitz Ingenieur GmbH (plant design, AutoCAD Plant 3D).

Terms, background and sources 26 terms on this page

Brief explanations for reference. They do not replace the standard or code itself.

DWG – AutoCAD drawing format

AutoCAD file format for drawings and 3D models; AutoCAD Plant 3D and AutoCAD P&ID also save in this format.

ZIP – ZIP archive

Compressed archive containing several files in one file. Windows opens it without additional software, e.g. catalog and pipe spec for Plant 3D.

SQLite

Database in a single file, without its own server. AutoCAD Plant 3D stores project data this way by default.

DN – Nominal size (DN)

Designation for the size of pipes, fittings and valves (Diameter Nominal). It is roughly the inside diameter in millimeters but is not an exact dimension.

Specified in DIN EN ISO 6708. Which outside diameter belongs to a DN is defined in the dimensional standards, e.g. DIN EN 10220 for steel pipes.

bar – Unit of pressure

Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”).

SKEY – Symbol key (SKEY)

Four-character symbol key for the isometric: the first two characters give the component type, the last two the end connection, e.g. VTFL = gate valve with flanges.

CPak

Folders in the AutoCAD Plant 3D content directory (e.g. “CPak Common”) containing catalogs and their component files. The program expects these folders unchanged.

WF – Wafer type (between flanges)

End code of a component connection in AutoCAD Plant 3D: wafer type, e.g. for orifice plates or butterfly valves between two flanges. Plant 3D then places only one through-bolt set.

FL – Flange

End code of a component connection in AutoCAD Plant 3D: flange. Plant 3D adds a mating flange with gasket and bolts.

STEP – Standard for the Exchange of Product model data

Vendor-neutral 3D exchange format for parts (ISO 10303), e.g. for equipment from the manufacturer.

PLANTPARTCONVERT

AutoCAD Plant 3D command: turns an AutoCAD block into a piping component by adding connections (ports).

BLOCK

AutoCAD command: combines objects under a name with a base point into a block definition that can be inserted as often as required.

BIM – Building Information Modeling

Planning, building and operating with a digital model that contains not only the geometry but also the properties of the components.

DCF

Project database file of AutoCAD Plant 3D and AutoCAD P&ID, e.g. ProcessPower.dcf (P&ID) and Piping.dcf (3D piping). It contains the project configuration and, in SQLite projects, also the project data.

PLM – Product Lifecycle Management

Management of all data of a product over its entire life – from development through manufacturing and operation to decommissioning. A PLM system is the software for this.

PLM connects the design data (see PDM) with purchasing, manufacturing, service and documentation. In plant design, for example, it is about reusing data from AutoCAD P&ID and AutoCAD Plant 3D over the entire life of a plant.

SQL – Structured Query Language

Query language for databases. “SQL Server” is Microsoft's database system; AutoCAD Plant 3D can store its project data there instead of in SQLite files.

PL – plain end

End code of a component connection in AutoCAD Plant 3D: plain end, e.g. of a pipe.

THDM – Male thread

End code of a component connection in AutoCAD Plant 3D: male thread.

THDF – Female thread

End code of a component connection in AutoCAD Plant 3D: female thread.

S1, S2

First and second connection (port 1, port 2) of a component in AutoCAD Plant 3D, e.g. in the catalog and in the isometric configuration.

BV – Butt weld end

End code of a component connection in AutoCAD Plant 3D: weld end (butt weld). Where BV meets BV or a plain end, Plant 3D places a weld.

ID – Identifier

Unique identifier, e.g. the number under which a record is kept in a database.

PCAT

AutoCAD Plant 3D catalog file with all components of a catalog, their sizes and properties. Technically it is an SQLite database.

PPL – Plastic weld

End code of a component connection in AutoCAD Plant 3D: plastic weld.

PSW – Plastic socket

End code of a component connection in AutoCAD Plant 3D: plastic socket.

R&I – Piping and instrumentation diagram

Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram).

Symbols and drawing rules: DIN EN ISO 10628-1 and -2. Identification letters for instrumentation: DIN EN 62424 or ISA-5.1.

Sources and origins