Plant Engineering Infobase · Questions from practice
Questions from practice: ReCap Pro
38 questions about ReCap Pro from our training courses and support – with the answer from practice. Free and without login.
ReCap Pro (38)
After the import I see hardly any points – what could be the reason?
The most common cause is an incorrectly detected input unit. In the import settings, check under Advanced whether meters or millimeters is set. If millimeters is set, a range filter of 40, for example, is interpreted as 40 mm instead of 40 m and almost all points are filtered out. Correct the unit, confirm changed values with the Enter key and import the scans again in a new project.
For IT security reasons, our workstations may only save to network drives. How can I still work smoothly with large point clouds?
Provide a dedicated point cloud computer with sufficient local SSDSSD – Solid State Drive Fast data storage without moving parts. Background and sources › storage and access it via Remote Desktop. The data then stays local on that computer, while you work from your own workstation.
Where should I save a new ReCap project, and what should I watch out for with the project name?
Create the project folder yourself in Explorer beforehand – unlike Plant 3D, ReCap does not create its own project folder. Under New > Project from file import, enter a name and then select this folder. Work on a local SSD drive if possible; network drives are much slower, and you should avoid folders synchronized with cloud storage. Avoid umlauts and special characters in names to prevent problems during import and sharing.
How do I add more scans to a project that has already been registered?
Open the project and select Import. You return to the import page and can add the additional scan folders by drag and drop. Check the import settings (unit, filters) and start the import. Then select Continue Registration so that the new scans are matched to the existing ones, and complete the process with indexing.
The export from the FARO software to ReCap does not work – how can I still get the scan project into ReCap?
You want to continue processing FAROFARO Maker of laser scanners (FARO Technologies); “Focus” is its scanner series. Background and sources › scans in ReCap. ReCap reads FARO data directly; an export from the FARO software is not necessary. FLSFLS – FARO scan file Single scan file of a FARO laser scanner. Background and sources › scans and the FARO project formats FWSFWS – FARO SCENE workspace Project file of older versions of the FARO software SCENE. Background and sources › and LSPROJLSPROJ – FARO SCENE project Project file of newer versions of the FARO software SCENE. Background and sources › are supported. 1. Create a new project in ReCap. 2. Import the FARO project file or the scans; for FLS scans always import the complete scan folders, not just the individual file. 3. Let ReCap process the data and check the result. Advantage: you save the intermediate step and work directly with the original data.
I imported only the scan file and the result is unusable – what went wrong?
With many terrestrial scanners (e.g. .fls format), each scan comes with a folder containing additional structure and the image information. So import the complete scan folders, not just the individual file. The most reliable way is to drag and drop the folders from Explorer onto the target area in the import window. ReCap converts the data into its own RCSRCS – ReCap scan file Scan file of Autodesk ReCap. Several RCS files together form a ReCap project (RCP). Background and sources › format during import.
How do I check whether my computer is suitable for point cloud processing in ReCap?
Under Settings > System, at the very bottom, you will find the Info section with details on the graphics card, memory and processor. For import, registration and indexing, a powerful multi-core processor and plenty of memory are important. Because a large amount of data is written, the project should be on a local SSD. For mesh models, a higher number of usable processor cores speeds up the calculation considerably.
Can I open the project while ReCap is still indexing?
We advise against it. Only indexing completes the registration – until then, the data is held only in a temporary cache. If you choose Launch Project before indexing reaches 100%, ReCap may hang or crash. So wait until the progress barbar – Unit of pressure Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”). Background and sources › is complete and all RCS files have been written to the project's support folder.
Which values should I choose for decimation and filters during import?
Decimation thins out the point cloud to a minimum spacing: the larger the value, the faster but also the more incomplete the result. For small piping, a few millimeters (about 1–2 mm, no more than 5 mm) make sense; alternatively, turn decimation off completely. The noise filter (e.g., aggressive) removes interference such as people walking past. Use the range filter to limit the range, e.g., for indoor spaces to the area actually needed.
How do I create a surface model (mesh) from a point cloud for use in other programs?
Save the project and start mesh creation. In the following dialog, select the scanner type used, a high quality setting (needed for piping so that round geometry is preserved) and the number of processor cores. The calculation is very compute-intensive and can take hours. You export the finished mesh, e.g. as an FBXFBX Autodesk exchange format for 3D models with meshes, textures and animations. Background and sources › file; it is usually much smaller than the point cloud and can be reused in Navisworks or Inventor.
When do I use window, fence or plane?
Window for compact, clearly delimited areas; Fence for irregularly shaped or angular areas; Plane for a continuous surface such as a wall or floor – even if objects stand in front of it.
How do I reduce a large scan project to a few scans without damaging the original?
Save the registered and aligned project to a new folder with Save As. In this copy, delete the scans and regions you do not need, including their content. The old RCS files are then still in the support folder, however – only another Save As of the cleaned-up copy really reduces the data. Then delete the intermediate versions. Do not delete anything in the master project; only hide it.
The model looks coarse and incorrectly textured in the browser. Did the processing fail?
No. The web viewer shows only a low-resolution proxy. Download the mesh – it is high-resolution and correctly textured.
What is the difference between an Aerial and an Object project?
Aerial uses images with geotag data and GCPGCP – Ground Control Point Ground control point: a point with known coordinates on site that is marked on the images. It makes a model from photos true to scale and correctly positioned. Background and sources › coordinates; the model is scaled and georeferenced, and a GeoTIFF is also possible. Object uses images without geotag data and delivers a textured mesh, but no GeoTIFF.
Why is the GeoTIFF output missing for Object Project?
The images have no geotag data and there are no GCPs – a georeferenced orthophoto is therefore not possible.
How much should the photos for a photo project in ReCap overlap?
By 60–80 %. For aerial images, the overlap is especially critical for the result.
Does Smooth change the number of mesh nodes?
No. Smooth evens out irregularities and flattens the mesh; the number of vertices remains the same.
How can I tell whether the registration of my scans is good enough?
After registration, ReCap shows a registration report with the scans and their overlap. Connections marked green are fine; with overlaps of more than about 50% you usually get good results, lower values are marked yellow or red. Also check visually, e.g. from above, whether walls and edges lie exactly on top of each other.
How many ground control points (GCPs) do I need for an Aerial Project?
At least three. Each GCP is marked on at least four images.
When do I compute the mesh locally, and when in the cloud?
Locally for small to medium-sized projects, without Flex tokens. Cloud processing consumes Flex tokens and requires a signed-in Desktop Connector with a connected cloud drive.
Which output do I choose when processing an Aerial Project – RCM, RCS or GeoTIFF?
RCMRCM Autodesk ReCap mesh file, e.g. the textured 3D mesh from photos or drone images. Background and sources › for a textured mesh (presentation, context model), RCS for further processing as a point cloud in ReCap Pro or AutoCAD, GeoTIFF for a georeferenced orthophoto (site plan, background image).
What is the difference between survey points and “Update origin”?
The survey point calculation affects the registration; “Update Origin” sets the origin and orientation of the entire project manually. The two tools are independent of each other.
Can I measure angles in RealView?
No. In RealView you can only measure distances; you measure angles in the 3D view.
How do I export only part of the point cloud as a separate file?
Define the desired region, e.g., via limit box and selection, and hide all other regions – only visible regions are exported. Then choose Export, set the point spacing (dense, e.g., 1 mm) and save the file. The result is a pure RCS point cloud without scan positions that loads much faster. Since the origin is preserved, all exported regions are correctly positioned relative to each other in other programs.
Do I have to re-register individually exported areas when I merge them again?
No. They can be imported back into a common project or referenced in AutoCAD; the original position is retained.
How do I divide a large point cloud into regions, e.g. rooms or levels?
Use the selection tools (window, fence, plane) to select points and define a new region from them. With the plane tool, ReCap detects surfaces such as walls; select points that are as far apart as possible for this. Points that do not belong can be deselected and removed. In the project navigator (bottom right) you can see all regions and scan positions, group scans by dragging and show or hide regions.
In which unit do I enter the coordinates of the survey points?
In meters.
Do I have to type in each survey point individually?
No. With “Upload survey points” you import a TXTTXT Plain text file without formatting. Background and sources › file with lines “Name X Y Z” or “Name North East Elevation”.
Why should I change the perspective so often when taking photos for a photo project?
This covers blind spots, captures more of the object and improves feature matching between images.
When does automatic registration work reliably?
When each scan position could be captured from the previous one (line of sight between the stations).
Can I define a separate origin for individual derived subprojects (e.g. for each hall bay)?
Technically yes. However, the subprojects will then no longer match and produce incorrect positions when combined. So define the origin once in the overall project and keep it for all derived projects.
Do I have to remodel classified mesh objects in Revit?
Not necessarily. With the ReCap plug-in for Revit, you insert classified mesh objects directly as Revit families.
Can I restore permanently deleted points?
Only as long as the project has not been saved again via “Save As”. Therefore save intermediate states normally.
How do I align the point cloud with the plan and define my own origin?
First disable perspective in the display settings. Then enable the origin there and select Update Origin. Click the desired origin, e.g., a building corner, and then align the X-axis with a wall surface (toggle between surface and axis alignment with the Ctrl or Alt key). The Z direction results from gravity and should not be changed; you can set the Z height, e.g., to the floor. Check the result in plan view.
Which insertion point do I choose when attaching the point cloud?
Usually 0,0,0 – provided the point cloud is already correctly referenced and aligned in ReCap.
Some scans were not registered automatically – how do I assign them manually?
Select the unregistered scan and a neighboring scan for manual registration. In both views, place the same point on three surfaces with different orientations, e.g. two opposite walls and one perpendicular to them. Avoid glass, curved objects such as vessels and moving parts such as doors. Use the intensity display to check whether someone walked through at that spot. Then merge the scans, accept the result and index.
Can I align the origin with a grid coordinate from my floor plan?
Yes. Select Update Origin again, snap to the reference point in the point cloud and enter the X, Y and Z coordinates that this point has in your plan. The point cloud is then moved so that it is correctly positioned relative to the floor plan. If possible, define the origin once in the master project and do not change it afterwards – otherwise derived projects and exports will no longer match.
Is Autodesk Docs still available as a destination for ReCap projects?
Yes. Autodesk Docs and ACCACC – Autodesk Construction Cloud Autodesk cloud platform for design data and collaboration; called Autodesk Forma since 24 March 2026. Background and sources › remain valid destinations with a full point cloud viewer; Forma Data Management is also available. Autodesk Drive on its own offers only a simple file preview.
The questions come from our training courses and support sessions – anonymized, without customer or project data. Menu paths refer to current German program versions and may differ by version; the answers do not replace checking in your own project.

Before you go …
Don't miss any training dates, C³ invitations and news on AutoCAD Plant 3D and P&IDR&I – Piping and instrumentation diagram Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram). Background and sources ›.
Our newsletter only arrives when there's something important – concise and with tips from practice.
Technically responsible: A. Seitz, Managing Director of A. Seitz Ingenieur GmbH (plant design, AutoCAD Plant 3D).
Terms, background and sources 13 terms on this page
Brief explanations for reference. They do not replace the standard or code itself.
- SSD – Solid State Drive
Fast data storage without moving parts.
- FARO
Maker of laser scanners (FARO Technologies); “Focus” is its scanner series.
- FLS – FARO scan file
Single scan file of a FARO laser scanner.
- FWS – FARO SCENE workspace
Project file of older versions of the FARO software SCENE.
- LSPROJ – FARO SCENE project
Project file of newer versions of the FARO software SCENE.
- RCS – ReCap scan file
Scan file of Autodesk ReCap. Several RCS files together form a ReCap project (RCP).
- bar – Unit of pressure
Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”).
- FBX
Autodesk exchange format for 3D models with meshes, textures and animations.
- GCP – Ground Control Point
Ground control point: a point with known coordinates on site that is marked on the images. It makes a model from photos true to scale and correctly positioned.
- RCM
Autodesk ReCap mesh file, e.g. the textured 3D mesh from photos or drone images.
- TXT
Plain text file without formatting.
- ACC – Autodesk Construction Cloud
Autodesk cloud platform for design data and collaboration; called Autodesk Forma since 24 March 2026.
- R&I – Piping and instrumentation diagram
Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram).
Symbols and drawing rules: DIN EN ISO 10628-1 and -2. Identification letters for instrumentation: DIN EN 62424 or ISA-5.1.
Sources and origins
- Wikipedia: Solid-state drive (for SSD)
- FARO Technologies (for FARO, FLS, FWS, LSPROJ)
- Autodesk Help (for RCS, RCM)
- BIPM – International System of Units (SI) (for bar)
- Wikipedia: FBX (for FBX)
- Wikipedia: Ground control point (for GCP)
- Wikipedia: Text file (for TXT)
- Autodesk (for ACC)
- ISO – International Organization for Standardization (for R&I)
- IEC – International Electrotechnical Commission (for R&I)