Plant Engineering Infobase · Questions from practice
Questions from practice: Plant 3D – 3D model
117 questions about Plant 3D – 3D model from our training courses and support – with the answer from practice. Free and without login.
Plant 3D – 3D model (117)
How do I flip a fitting during insertion if it is placed with the wrong connection?
While inserting, press the Ctrl key to cycle through the component's connection points, then place it. To check whether the connection is correct, turn on the connection indicators under visibility at the top and click the connection point between the components; Substitute Part shows the connection type (e.g. butt weld or threaded connection). To remove an unwanted connection, select the connection point and press Delete.
How do I select an entire connected line and hide the rest?
First make sure the affected layers are not locked. Click a pipe, right-click > Add to Selection > All Connected Parts (or connected line number). Then right-click again > Isolate > Isolate Objects – only the selected line remains visible. In the Properties palette, the entry "*VARIES*" tells you that the selection contains different line numbers.
In a drawing, all colors look very dark – how do I get the normal display back?
Reset the visual style to the default by right-clicking. In the support case, the display was back to normal afterward.
Why is no isometric generated for my pipe?
The prerequisite is that all connected parts have a line number – without a line number, no isometric is created. If an error notification appears at the bottom right of the status barbar – Unit of pressure Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”). Background and sources ›, click it to open the log; it states why creation failed (e.g. database or network problems when generating the intermediate file). Also check whether a spec update is recommended, and run it first.
Do I have to export isometrics to pass them on as DWG?
No. Isometrics are already regular AutoCAD DWGs. They are located in the project's Isometric folder and can be passed on directly.
Plant 3D places an elbow with an exclamation mark even though my piping spec does not contain an elbow. Why?
If a required component is missing from the piping spec, Plant 3D inserts a placeholder at that point so you can continue drawing. The exclamation mark indicates this; click it to see the cause. Add the missing component (e.g., an elbow) to the piping spec and update the project; the placeholders can then be replaced. Whether placeholders are visible is controlled via the visibility settings.
My valve does not connect to the pipe when inserted – what am I doing wrong?
You want to place a valve cleanly in an existing line. 1. Open the Spec Viewer via Home > Part Insertion, select the valve and click "Insert in Model". 2. If the insertion point is not at the desired connection, switch it with Ctrl. 3. Select a specific object snap: hold down Shift, right-click in the drawing area, e.g. Midpoint or Nearest. Many object snaps active at the same time can mask the desired point – reduce them if necessary. 4. Click a point on the pipe, specify the rotation or confirm with Enter. This places the valve at the desired position in the line.
Suddenly I can no longer zoom in the ortho layout – what is going on?
You want to zoom freely in the layout again. Often a large, unlocked viewport is active in the background – then every zoom only affects its content instead of the sheet. 1. Double-click outside the viewports to switch to paper space. 2. Select the interfering viewport and set "Display locked" to "Yes" in the Properties palette (alternatively via the lock in the status bar). Locked viewports protect against accidental zooming and panning. 3. Zoom out and delete the viewport if it is not needed. 4. If it comes from the drawing template (DWTDWT – Drawing template AutoCAD template file (drawing template): new drawings take their layers, styles and settings from it. Background and sources ›), remove it there as well. This keeps new ortho layouts free of it too.
How do I create a new Plant 3D project based on our company template project?
1. In the Project Manager, choose "New Project" and specify the name and location. 2. Enable the option "Copy settings from existing project" and select the Project.xml file of the template project. 3. Check the following pages (paths for P&IDR&I – Piping and instrumentation diagram Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram). Background and sources › and 3D drawings, symbol standard, database) and confirm with Next. 4. At the end, check the box to open Project Setup: if Project Setup opens without an error message, the project was created correctly. Note: a copied project does not automatically inherit later improvements to the template.
A drawing can no longer be opened – how do I rescue it?
Open the file via the Drawing Recovery Manager, save it again, and use it to replace the defective DWGDWG – AutoCAD drawing format AutoCAD file format for drawings and 3D models; AutoCAD Plant 3D and AutoCAD P&ID also save in this format. Background and sources ›. In projects, do not change the file name.
Why is the weight of my structural steel profiles wrong after a change?
The weight is taken over only when placing from the catalog. If you change the length or profile afterward, it is not recalculated – reset the profile or correct the value. For custom profiles, the mass is stored in the profile XML.
Does Plant 3D warn me when I connect a component from a different piping spec?
When routing, Plant 3D offers only parts from the active spec. If the connection codes match, however, a part from a different spec can be connected without a warning. A spec break then appears on the isometric. If in doubt, check the spec in the part's properties.
Plant 3D keeps resetting my nozzle designation (e.g. N1.1 or M1) – how do I name it freely?
In the tag format of the nozzle, change the expression to “Free-form value”. You can then enter any designation.
Structural steel or other objects disappear in the “Shaded” visual style – what helps?
Known display issue. Set the system variable FASTSHADEDMODEFASTSHADEDMODE AutoCAD system variable: turns the newer cross-platform 3D graphics system on (1) or off (0). The variable no longer exists in AutoCAD 2027. Background and sources › to 0 (up to AutoCAD 2026) or disable hardware acceleration; alternatively, use a different visual style. For very large drawings, split the model across several DWGs and view the complete model in Navisworks.
Can I export several lines into one common PCF file?
No. Plant 3D generates one PCFPCF – Piping Component File Text file with which AutoCAD Plant 3D passes piping data to the isometric generator and to other programs. Background and sources › file per line number.
In one viewport objects are missing, in others they are not – why?
The layers are probably frozen in the viewport (VP Freeze). Double-click inside the viewport and thaw the layers in the Layer Manager in the “VP Freeze” column.
Which isometric settings are particularly useful in practice?
In Project Setup under Isometric DWG Settings: switch off automatic split points and set split points yourself – this keeps unchanged sections identical in a revision. Enable weld numbering (including field welds). Output slope in mm/m instead of percent, since on site it is usually measured with a folding rule. Show insulation in isometrics. The "Overwrite existing files" option can be preset directly. Small nominal sizes are displayed in color or with a smaller symbol scale via the theme settings.
Why doesn't the date in the isometric title block show the current date?
The Date and Create Date fields refer to the template (DWT) and do not change. The plot date is updated with every print, the save date with every save. Use one of these fields or enter the date manually.
Do I need a separate elbow in the catalog for every angle?
No. With the custom bend function, any angle from 1° to 90° is possible; the angle can be adjusted via dynamic input. On the isometric, each custom bend appears as a separate part; you can also output the angle via the bill of materials table of the iso template.
Objects disappear in the 3D model or AutoCAD crashes when orbiting – what can I check?
As a test, disable hardware acceleration. In three support cases (objects disappeared after switching to Windows 11, crash when orbiting in 3D, structural steel invisible), this was the solution.
Can the weld list be changed so that it numbers flanges or flanged joints?
No, the weld list cannot be switched to connections or flanges. As a workaround, give each flange its own number in a property (e.g. via Excel import in the Data Manager) and create a dedicated label for it in the ISOISO – International Organization for Standardization International Organization for Standardization in Geneva: it develops standards that apply worldwide (ISO standards). Background and sources › style.
Components have lost their Plant 3D properties – can they be repaired?
If Plant 3D components have lost their properties (they are just a pipe or an inline object without data), they cannot be repaired. Restore the drawing from a backup or place the affected components again. For this reason, back up your project regularly.
Insulation is not displayed on fixed-length pipes – how do I show it?
The system variable PLANTINSULATIONMODEPLANTINSULATIONMODE AutoCAD Plant 3D system variable: determines whether insulation on pipes is displayed. Background and sources › switches the insulation display. If a pipe after a flange is always placed with an unexpected length, check the minimum or fixed length entered in the Spec Editor.
How do I create an IFC file from my Plant 3D model?
You want to pass on a Plant 3D model in IFCIFC – Industry Foundation Classes Open exchange format for building and plant models (BIM), standardized as ISO 16739. Background and sources › format to other disciplines. Plant 3D does not export directly to IFC; the route is via an AutoCAD copy. 1. Open the model drawing and run EXPORTTOAUTOCADEXPORTTOAUTOCAD Command in AutoCAD Plant 3D and AutoCAD P&ID: saves a copy of the drawing in which the plant objects are converted into simple AutoCAD objects – readable without plant software. Background and sources ›. This creates a copy in which the Plant objects are converted into simple AutoCAD objects; the original remains unchanged. 2. Open the exported drawing in the Architecture toolset (alternatively MEPMEP – Mechanical, Electrical and Plumbing Collective English term for building services: heating and ventilation, electrical and plumbing. Roughly equivalent to the German TGA; AutoCAD MEP is the matching AutoCAD toolset. Background and sources › or Civil 3D). 3. There, export the active drawing as IFC; a LOGLOG Log file: a program writes into it what it has done and which errors occurred. Background and sources › file is created alongside the IFC file. Note: the intelligent behavior of the Plant objects is lost in the copy. This gives you an IFC file for coordination without changing your project.
How do I check whether my project still contains wrong or old references?
In the Project Manager, right-click the project name and select "Audit Project". Then press F2F2 Function key in AutoCAD: shows and hides the extended text window with the command history – where, e.g., audit reports appear. Background and sources › to open the text window with the audit log – there you can see errors found, e.g. references to templates or paths of another project. Run the audit again after a correction until no more errors are reported. Drawings that are listed in the project but no longer exist can be removed from the project by right-clicking.
My ortho view is not generated or aborts – what could be the cause?
Often caused by individual, highly detailed objects (many faces, thousands of individual parts) or by moved external references. Exclude suspect objects as a test, simplify them (e.g. contour simplification in Inventor) and avoid surface models. External references are not derived and should be inserted at 0,0.
My Plant 3D drawing becomes extremely slow after importing manufacturer models – what can I do?
Very detailed imports (thousands of individual parts, surfaces, hundreds of MBMB, GB, TB – Megabyte, gigabyte, terabyte Units for data volumes: 1 GB (gigabyte) = 1,000 MB (megabytes), 1 TB (terabyte) = 1,000 GB. Background and sources ›) overwhelm AutoCAD. Simplify models before importing (e.g. contour simplification in Inventor), use blocks instead of copied solids, use Plant 3D gratings instead of solids, and distribute the model across several DWGs. It is better to display detailed models in Navisworks (NWC/NWDNWC – Navisworks cache file File that Navisworks creates when loading a foreign file so that it loads faster the next time. Background and sources ›NWD – Navisworks file (published) Navisworks file in which all models are stored permanently – for sharing, also with the free Navisworks Freedom. Background and sources ›).
How do I pass on an ortho drawing as a plain AutoCAD drawing?
Right-click the layout tab › “Export Layout to Model”. This creates a normal DWG with 2D geometry that can be edited further, e.g., in AutoCAD Mechanical. If no dialog opens, set FILEDIAFILEDIA AutoCAD system variable: determines whether file dialogs open (1) or AutoCAD asks for file names on the command line (0). Background and sources › to 1.
Gaskets are missing on a spectacle blind, or the connection is not made – what helps?
Place the spectacle blind again and pull the adjoining valve to the connection point with the STRETCH command. In the support case, the connection was not created using the grips.
The reference to the continuation line is missing on the isometric – why?
Check the connecting line: in the support case, it had no spec assigned. For flat-face flanges based on a loose flange, the continuation is also missing (only one grip) – use a flange type with two grips there.
Numeric values in the isometric BOM have a shifted decimal point – what can you do?
In Plant 3D 2026 Update 1, numeric values in the isometric BOMBOM – Bill of Materials Bill of Materials – parts or material list. In AutoCAD Plant 3D the BOM-ATTRIBUTES section of Iso.atr defines the component properties on the isometric. Background and sources › are output with a shifted decimal point (e.g. 14500 kg instead of 145 kg). The bug is known to Autodesk; until it is fixed, generate the isometric drawings with version 2025.
How do I assign line numbers to many pipes afterwards?
Open the Data Manager, expand the pipe lines in the tree structure and select the parent level so that all line segments appear in the table. Use the magnifying glass icon at the start of the row to zoom to the respective line, then enter the number in the column – the tag and, with the appropriate configuration, the layer are adjusted automatically. As a rule, assign numbers from the start, provisional ones if necessary; unnamed lines lead to confusion later.
Why does the bill of materials show only a generic description instead of the order text?
In the table setup, the family designation column is used instead of the size designation. To change this: Project Setup > Isometric DWG Settings > table setup, or for orthos under "Title Block Setup" > Tables. Select the long size description, i.e. the order text. Further columns (e.g. material) can be added. Useful options: list pipes as cut pieces, output length instead of quantity, show bends separately. For orthos, activate the required BOM types (pipe, equipment, nozzles, steel) so that they are available for selection.
Glued joints are on the wrong layer in the isometric drawing – what is the cause?
Glued joints appear on the isometric drawing on the layer “Symbol” instead of the weld layer if the model was created in the German 2024 version; in English versions they are on “Weld”. What matters is the language version in which the model was created. Autodesk has reported the bug to development.
Some parts are missing in the Report Creator – what could be the reason?
Common causes from support: (1) Status “Existing” – the report filters out existing parts; (2) for a pipe, “Fixed length” is empty instead of 0 – remove the pipe from the report query and add it again; (3) the component type (e.g. supports) is not included in the report template – add it in the RCF file.
How do I save an interim state of my 3D model for comparison before making major changes?
Export the drawing to AutoCAD and save it under the same name with a suffix such as “_ACAD”. You can store this frozen drawing as a reference or keep it with the related files. Do not rename project folders afterward, otherwise reference paths are lost.
When routing, pipes and elbows are combined into a group – how do I make them individual components again?
You want to place pipes and elbows as individual components: Plant 3D can create changes of direction as pipe bends of a bent pipe; a bent pipe is saved as a group. 1. On the Home tab, in the "Part Insertion" panel, check whether "Toggle Pipe Bends" (Pipe Bends) is active and switch it off for normal fitting elbows. 2. In Project Setup, check whether routing with separate components or with bent pipe is set. 3. Bent pipes that have already been routed can be converted into individual components (pipes and elbows) and vice versa. Advantage: you consciously decide whether elbows are created as fittings with welds or as pipe bends without welds.
After drawings have been copied into a new project, Plant 3D reports elements without a reference – what should I do?
If Plant 3D reports elements without a reference after drawings have been copied into a new project, connections to a removed or lost drawing are damaged. Delete these connections and set them again by right-clicking, or remove all drawings and load them again together with their references. Then check the project’s DWG folder.
Why is structural steel missing in my ortho view?
Ortho does not derive external references. For the ortho, use the individual project DWG with the solids instead of an xref. Always insert external references at 0,0 in Plant 3D.
Parts of the model disappear when binding a reference – what should I do?
If parts of the model disappear in Plant 3D 2025/2026 when binding a reference, AUDIT, PURGE, PLANTAUDITPLANTAUDIT Command in AutoCAD Plant 3D and AutoCAD P&ID: checks the drawing against the project database and fixes errors in the synchronisation between the two. Background and sources › or a new project will not help. Copy the content into a new drawing based on the original Autodesk template (DWT) – binding works there; bound references appear as a block, which you then explode.
When connecting to a vessel nozzle, an error about facing or pressure rating appears – what can I do?
The nozzle must match the line's piping spec in units, pressure rating, facing, and nominal size. Select the nozzle and open Edit Nozzle: set metric, and choose nominal size and pressure rating to match the piping spec. If the nozzle catalog has no nozzle with the required facing, create a suitable nozzle in the nozzle catalog (Nozzle catalog) in the Spec Editor and enter the facing there. If the catalog is located in the shared content folder, it is available to all users. Related support question: “Flange and valve do not connect (property conflict) – may I adjust the valve's pressure rating?” Yes. Pressure rating, facing, and nominal size must match, but the pressure rating is used only for the connection. Set the valve to the flange's pressure rating and leave the actual rating (e.g. PN 40PN – Nominal pressure rating Designation for the pressure rating of flanges and valves (Pressure Nominal), e.g. PN 16. It corresponds roughly to the allowable pressure in bar at room temperature; at higher temperatures, less is allowed. Background and sources ›) in the long description (size) – it appears in all bills of materials.
After inserting a supplied equipment model, the proportions are wrong – my pipes look tiny. What is the reason?
You want to adopt third-party models true to scale: the supplied model is often drawn in meters instead of millimeters. 1. Open the supplied file and check the drawing unit with UNITS or the system variable INSUNITSINSUNITS AutoCAD system variable: sets the drawing unit for inserting, e.g. 4 = millimetres, 6 = metres. AutoCAD uses it to scale blocks and references when inserting. Background and sources ›. 2. If a unit is set, AutoCAD automatically scales blocks and external references to the unit of your drawing when inserting them. If it is set to "Unitless", no conversion takes place – in that case scale the model with SCALE (factor 1000 for m → mm) or request it in mm from the supplying company. 3. Then check the position and size in the model and in the ortho. Advantage: equipment, nozzles and pipes fit together to scale again.
When creating equipment, Plant 3D takes over the values of the last equipment – how do I start fresh?
When creating equipment, choose the “new” variant instead of using the most recently used equipment as a template.
Can the drawing property “Author” be transferred automatically to the iso title block?
Only to a limited extent: the isometric drawing is a pure AutoCAD drawing without a connection to the project database, and the drawing property Author exists only for P&ID, Plant 3D and ortho drawings. General fields such as the Windows login name or the iso title block attributes can be filled automatically; otherwise use a normal attribute to fill in.
Why does the connection pipe style split the line and not show valves?
This is also the case in the Autodesk standard: the spool style is a fabrication instruction and shows only the parts welded together. For a continuous line with all components, use an isometric style.
After exchanging a drawing with a colleague, Plant 3D no longer finds the nozzles – why?
Each catalog part has an internal, unique identifier. If you and your colleague have each created the same part yourselves in your local catalogs, these identifiers differ and the part is not found. In this case you have to place the nozzle again. You can avoid the problem permanently by having all users work with identical catalogs via the Shared Content Folder.
My isometric coordinates should refer to a different plant origin – how do I do that without moving the model?
In the advanced settings of isometric creation, enter an offset position. Alternatively, move the model. Negative prefixes for the coordinate directions can (before version 2024) only be set in IsoConfig.xml.
How do I keep large piping models manageable?
Set up first, then draw: define tags, layers and media, and define the line tags exactly as in the P&ID. Assign line numbers from the start and split the lines into separate drawings by medium (e.g. water, gas). This keeps the individual drawings lean, and you can find every line quickly.
Generating orthos takes a long time – how is it faster in AutoCAD Plant 3D 2026?
You want to generate orthos faster: since version 2026 the “Ortho Generation” dialog box has two options that let Plant 3D skip views. How to proceed: 1. Generate the orthos as usual until the “Ortho Generation” dialog box appears. 2. Activate “Skip views that are already up to date”. Views that are already current are then not regenerated. 3. If required, activate “Skip views with missing models”. Views with missing models are then skipped. 4. Afterwards check the views with missing models: they have not been updated. Re-insert the missing models and generate these views again. Note: Autodesk does not state how much faster it is. Your advantage: Plant 3D only regenerates the views it needs. Background: wish from the Idea Station, idea 12220870 (43 votes, as of 07.11.2026); Autodesk does not state a version in the status of the idea. Source: Autodesk Help, What’s New in AutoCAD Plant 3D 2026, “Ortho Enhancements”. Next step: if your project behaves differently than described, write to support@seitz-ingenieure.de – we will look at it together via remote session.
How do I represent a hose in Plant 3D?
Use a piping spec with a pipe that is designated as a hose. Draw the route as lines or a polyline (the first piece straight) and convert it into a pipe with Line to Pipe. In the bend settings, specify that bends are treated as pipe and select a large bend radius – this creates a continuous, curved hose. If you want to change the route later, keep the sketch line during the conversion and put it on a separate layer.
How do I keep the line number when copying piping?
Set the system variable PLANTCOPYLINENUMBERPLANTCOPYLINENUMBER AutoCAD Plant 3D system variable: determines whether the line number is kept (ON) or not (OFF) when copying from an existing line – in the P&ID and in the 3D model. Background and sources › to ON.
My model with many references becomes sluggish and orthos fail – what should I check?
If a reference is not placed at the common plant origin, all other references will be off and orthos cannot be generated – so insert references at the origin. Avoid multiple overlaid references. Add manufacturer valves to the spec as custom parts, not as references. Keep projects not locally but on a backed-up network drive.
Can I recover the centerline of a routed pipe as a 3D line afterwards?
There is no direct command for this. When creating pipe via Line to Pipe, you can answer No to the question whether the line should be deleted – the centerline is then kept. For lines already routed, the only options are retracing via the vertices or the PCF export: it contains the coordinates of the line points; however, bends are represented only by their intersection points.
Objects end up in the wrong place when placed, e.g. steel beams – could large coordinates be the cause?
Yes. In AutoCAD/Plant 3D, work close to the origin (support recommendation: up to about 100 m distance). In one case, a steel beam was placed correctly only after the reference line was moved to the origin. For isometrics with plant coordinates, an offset can be specified in the advanced settings of isometric creation.
Where do I correctly enter the service of a pipe line in the 3D model so that I do not have to override it on every component?
You want to maintain the service once and see it on all components: piping components and fasteners acquire service, insulation type and insulation thickness from the line group (P3dLineGroup) by default. 1. First assign a line number to the components – only then do they belong to a line group. 2. Enter the service on the line group, e.g. in the Data Manager under Pipe Lines, instead of overriding the value on the individual component. 3. Check in the Data Manager whether all sections have adopted the value. Advantage: if the service changes, all acquiring components and tags based on them adapt automatically.
Message “non-parallel connections cannot be connected” – what does it mean?
Message “non-parallel connections cannot be connected” when moving a flange with its grip: the line has a small offset. Pipes compensate for it within a tolerance, rigid fittings do not – determine the offset with point filters and align the line.
On the isometric, the flow arrow lies behind the pipe line – how do I bring it to the front?
A flow arrow placed as an ISO annotation can lie behind the pipe line on the finished isometric; this cannot be set in the iso style. Select the arrow on the isometric and bring it to the foreground with right-click → Draw Order → Bring to Front.
How do I get a column grid into an ortho view to scale?
Draw the grid from lines and MTextMText – Multiline Text Paragraph text in AutoCAD: multi-line text as one object, with its own formatting per character. Background and sources ›, copy it with “Copy with Base Point”, and paste it at the same point in the model space of the viewport. Thaw the layer that is frozen in the viewport and scale the grid by the scale factor (1:30 → 30). After every ortho update, the layer freezes again – then thaw it again.
How do I model a pipe with a 45° bevelled end as a separate Plant component?
You want to manage a special shape such as a 45° bevelled pipe end as a real Plant component. 1. Model the shape as a 3D solid for each required nominal size and create a block from each. 2. Add connections to the block with PLANTPARTCONVERTPLANTPARTCONVERT AutoCAD Plant 3D command: turns an AutoCAD block into a piping component by adding connections (ports). Background and sources › (Add, Reverse if necessary, Accept, Exit) and save the drawing immediately. This creates XML and PNGPNG Portable Network Graphics: image format with lossless compression. Background and sources › files in the drawing folder, which you copy along when passing it on. 3. From the converted block, create a block-based component via the Custom Parts window or include it in a catalog and a piping spec. 4. Check the display on a test isometric. This way the component is connected to the line and taken into account in lists.
My isometric is overloaded – how do I get Plant 3D to split a line across several sheets?
You want clear isometrics: 1. When creating the isometric, activate the option "Create Split Points Automatically" – Plant 3D then splits the line across several sheets depending on the drawing complexity. 2. Check the result. 3. So that the split remains the same in later revisions, save the split points in the model in the same session: status bar > isometric drawings icon > "Isometric Creation Results" > "Convert Split Points", select the iso style and line (alternatively the PLANTISOSPLITPOINTSPLANTISOSPLITPOINTS AutoCAD Plant 3D command: transfers the split points of an isometric into the 3D model as fixed points (“Convert split points”). Background and sources › command). Advantage: each sheet remains legible, and the sheet split is reproducible.
Branches without a tee produce a gap in the PCF file (e.g. for pipe stress analysis) – how do I avoid that?
First connect the branch with the same nominal size; the line then extends to the centerline of the main line. Afterward, change only the nominal size of the branch. This way no gap appears in the PCF file.
A drawing has disappeared from Project Manager but is still in Explorer – how do I get it back?
In this state, the drawing cannot be added back to the project. Restore it from the backup. If there is no backup, attach the existing DWG as an external reference to a new project drawing and redraw the content on top of it.
With a custom part, I cannot change the connection data at the second connection afterward – what should I do?
Enter the connection information (nominal size, end type, pressure rating) directly when creating the custom part. Changing it afterward at S2S1, S2 First and second connection (port 1, port 2) of a component in AutoCAD Plant 3D, e.g. in the catalog and in the isometric configuration. Background and sources › was a program error of an update in the support case; check whether a newer update is installed.
When creating a new drawing, an error message about the template appears. What is the cause?
Usually the assigned DWT template cannot be reached or is read-only (e.g. missing permissions on the template drive). In Project Setup under "Paths", check the entries for the P&ID and the Plant 3D drawing template and point to an accessible DWT via the three dots. In addition, each folder in the Project Manager can have its own template: right-click the folder > Properties > DWG Template. If the template is corrected only there or only in the paths, the error remains in the other case.
Objects on a hidden layer still appear in my ortho view – what do I check?
You want only the desired objects to appear in the ortho: first check which layer the objects are on. 1. Select the object in the model drawing and read the layer in the Properties palette (Ctrl+1). 2. If it is on DEFPOINTS, move it to a separate layer – DEFPOINTS is a special layer for the definition points of dimensions, is never plotted and is not intended for model objects. 3. Save the model drawing, open the ortho drawing and regenerate the view in the Project Manager by right-clicking > Update View. Advantage: you once again reliably control visibility and plot output via your own layers.
The Data Manager reports an error when importing an Excel list – what should I check?
If the Data Manager reports an error when accepting an imported Excel list, even for individual rows, check the cells for special characters such as single hyphens. After removing them, the list can be accepted.
Plant 3D always crashes at a certain function, e.g. with structural steel commands – what helps?
If the crash occurs reproducibly with the same function, a clean uninstall followed by a reinstall helped in two support cases.
My equipment does not adopt the layer color and cannot be hidden via the layer – what is the reason?
You want equipment to receive its color and visibility via its layer. The cause is usually the underlying solid with a fixed color or its own layer: only objects in the block that lie on layer 0 and are set to ByLayer adopt the properties of the layer on which the block is inserted. 1. Back up the drawing first. 2. Set the source solid to layer 0 and color ByLayer. 3. Create a block from it. 4. Convert it into equipment with "Convert Equipment" (command PLANTEQUIPMENTCONVERTPLANTEQUIPMENTCONVERT AutoCAD Plant 3D command: converts a 3D model made of AutoCAD objects into equipment with nozzles and tag (“Convert Equipment”). Background and sources ›); in the dialog you define nozzles and assign the tag. After that, the equipment follows the layer – also when hiding.
How do I route pipes of different nominal sizes with the same bottom of pipe?
You want to route lines of different nominal sizes, e.g. on a pipe rack, with the same bottom of pipe (BOPBOP – Bottom of Pipe Bottom of Pipe – lower edge of the pipe. Lines with the same BOP rest at the same height on a pipe rack, for example, even with different nominal sizes. Background and sources ›). To do this, change the justification of the routing line. 1. On the ribbon, click Home > Elevation & Routing Line panel > "Center (current justification)". 2. Select a justification at the bottom edge from the list, e.g. "Bottom Left". 3. If necessary, enter a horizontal offset; negative values offset in the opposite direction. 4. Start "Route Pipe" and click the start and subsequent points. The routing line then lies at the selected edge instead of the pipe center. This way all lines rest flush without you having to convert elevations for each nominal size.
The angle specification is missing for olets on the isometric – why?
Check the line number of the olets: it must match the main line. In the support case, the olets had a different number; after matching them, the rotation angles were displayed.
On the isometric, the material number appears as a number (e.g. 14571.00 instead of 1.4571) – why?
This is a software bug that occurred in the support case with update 2026.1.
Is there a tool palette that automatically shows the components of my piping spec?
Yes. The command PLANTDYNAMICTOOLPALETTEPLANTDYNAMICTOOLPALETTE AutoCAD Plant 3D command: creates a tool palette with the components of the current piping spec. Background and sources › creates a dynamic palette with the components of the current piping spec.
Can I freely define the orientation of valve actuators on the isometric?
No. The actuator is displayed only in 90° increments; the actual angle is given alongside. Rotating expansion joints around the pipe axis can likewise not be displayed – indicate the orientation with an annotation or in the order text.
Dimensions in the ortho layout on additionally drawn lines show incorrect values – how do I correct this?
You want to dimension geometry added in the layout true to scale. AutoCAD automatically adapts associative dimensions on model objects in the viewport to the viewport scale; non-associative dimensions, e.g. on lines drawn in the layout, do not receive this adjustment – there the linear scale factor (DIMLFACDIMLFAC AutoCAD system variable: scale factor for linear dimensions: the measured value is multiplied by it before it appears as the dimension text. Background and sources ›) must be set manually. 1. Use LIST on a correct dimension to check which scaling or style override it carries. 2. For the incorrect dimensions, set the linear scale factor to match the scale of the viewport. 3. If you already have a correct dimension, transfer its dimension style to the others with MATCHPROP (Match Properties) and then check the dimension values. This way all dimensions in the ortho layout are correct.
Can I set up the isometrics so that valves are dimensioned end to end?
Yes. Project Setup > Isometric DWG Settings > Set Up Iso Style or dimension settings. In the string dimension section, you can specify for each component type, e.g. for weld or flanged valves, whether dimensions go to the center or end to end. Use "Add" to add missing component types. This is also where you set whether gaskets are dimensioned. The setting applies per iso style – check all styles in use (e.g. for different sheet sizes).
Why does the isometric bill of materials show DN values even though I use inch components?
The isometric bill of materials follows the project unit, not the spec. This cannot be changed.
Eccentric reducers are connected incorrectly on the isometric for some colleagues – why?
In the support case, it was a software bug that has been fixed in the current updates. Bring all workstations to the same, current update level.
Can AutoCAD MEP generate PCF files or isometric drawings?
Not without additional tools; the CADmepCADmep Autodesk Fabrication CADmep: add-on for AutoCAD for designing ventilation, piping and electrical installations with fabrication-accurate components. Background and sources › tools (in the AECAEC – Architecture, Engineering & Construction English for architecture, engineering and construction. At Autodesk this is the name of the “AEC Collection”, which includes AutoCAD with the AutoCAD Plant 3D toolset, Revit and Navisworks. Background and sources › Collection) generate PCF files. Recommendation: design round piping in Plant 3D with a piping spec and isometric, and combine the model as a reference in AutoCAD MEP or in Navisworks.
How do I display the nominal size on the isometric as “DN 50” instead of “50 NS” – or hide it completely?
Open the IsoConfig.xml of the isometric style and search for PropertyChangeScheme Name="Size". Under “Format” you find what appears in which order; under “Field”, which property is inserted for {0}. In the format, replace “NS” with “DNDN – Nominal size (DN) Designation for the size of pipes, fittings and valves (Diameter Nominal). It is roughly the inside diameter in millimeters but is not an exact dimension. Background and sources ›” and put it in front of {0}. If the nominal size should not appear at all, delete that line; the same applies to the elevation.
Weld points are missing on the isometric for elbows other than 90° – what helps?
Open the IsoConfig.xml of the style and, under Themes > Default Theme > Annotations, set the value “BumperDistance” to greater than 0.8 (e.g. 0.9). From version 2016, values up to 0.8 led to missing weld points and faulty isos.
After copying an ortho title block into the ISO style, fields remain empty – why?
If you copy an ortho title block into the ISO style, fields such as sheet number or creator remain empty because the isometric drawing needs its own iso title block attributes. Remap the attributes in the iso title block; fields without a link are normal attributes and are filled in by double-clicking or in the properties.
In one iso style the labeling (e.g. pipeline tag) is wrong and texts rotate when double-clicked – in the other style everything is correct. What is the reason?
You want the same clean labeling in every iso style: a common cause is a text style with a font whose name begins with "@" (e.g. "@Arial Unicode MS"). These fonts are intended for vertical text in Asian languages – Latin text is displayed rotated with them. 1. In the affected iso style, check the text style of the labeling (STYLE command) and assign a font without "@", e.g. isocpeur or Arial. 2. Each iso style has its own folder with its own settings (including isoconfig.xml); changes in one style do not apply to the others. If the tag definition is missing, take it from the working style – first back up the existing file by renaming it. 3. Then generate a test iso and check the tag and texts. Your advantage: consistent isometrics in all sheet formats.
All my pipes end up on layer 0. How do I set up automatic layer assignment?
In the Project Manager, open Project Setup > Plant 3D DWG Settings > Layer and Color Settings. Use “New” to create a setting, e.g. assign layers by line number (tag) and color by layer, and set it as current. For supports, “Same layer as pipe” is recommended. Note: The change can be applied to all open drawings – test it on a copy first. A prerequisite is that every line has a line number. Related support question: “My pipes are all on layer 0 even though layer by line number is set – why?” The layer follows the line number: without an assigned number, the line ends up on layer 0. Assign the numbers e.g. in the Data Manager under Areas > Piping (the magnifier jumps to the object) – the layer changes automatically. Under Plant 3D DWG Settings > Layer and Color Settings, check which setting is current, and apply changes to all open drawings with “Set as current”. Tip: set up first, then draw; if necessary, assign provisional numbers.
The Excel table for the iso title block is not recognized or keeps getting detached – what should I do?
If the Excel table (LDT) for the isometric title block is not recognized or keeps getting detached, check the attribute file of the title block: if it contains a large number of unnecessary entries (in this case several hundred), clean it up – the table is then read in again.
Insulation used to be on its own layer; in the current project it is on the layer of the pipe – where do I set this?
You want the insulation back on its own layer: this is not a project setting but the system variable PLANTINSULATIONUSEPARTLAYERPLANTINSULATIONUSEPARTLAYER AutoCAD Plant 3D system variable: determines whether the insulation is on the pipe's layer (1) or on its own layer (0). Background and sources › (Plant 3D 2023 and later). It is stored in the registry and applies per computer or user profile – after a new installation, a version change or on another workstation it is back at the default 1 (insulation on the layer of the pipe). 1. Enter PLANTINSULATIONUSEPARTLAYER on the command line and set it to 0. 2. So that color and transparency come from the insulation layer: PLANTINSULATIONCOLORPLANTINSULATIONCOLOR AutoCAD Plant 3D system variable: sets the colour of the displayed insulation; 256 = ByLayer. Background and sources › = 256 and PLANTINSULATIONTRANSPARENCYPLANTINSULATIONTRANSPARENCY AutoCAD Plant 3D system variable: sets the transparency of the displayed insulation; -1 = ByLayer. Background and sources › = -1 (default values). 3. Plant 3D creates the layer
After changes to the isometric style, Plant 3D only produces errors – what should I do?
Create a new isometric style based on a working style and adjust it slightly.
How do I display angle valves correctly on the isometric?
Angle valves need the iso symbol type VALVE-ANGLE and a matching SKEYSKEY – Symbol key (SKEY) Four-character symbol key for the isometric: the first two characters give the component type, the last two the end connection, e.g. VTFL = gate valve with flanges. Background and sources ›, because they work differently from straight-through valves. The actuator direction cannot be set freely – port S2 is always below the actuator.
The slope triangle is dimensioned incorrectly on the isometric – can I hide the dimensions?
Yes. In the IsoConfig.xml of the style, search for “NonSkewAngleTolerance” (default 1.5) and set it to 0 – the dimensions of the slope triangle are then no longer displayed. Afterward, check the display of the bend.
Since I inserted a weld list into the isometric style, no more isometrics are created – what helps?
Remove all tables (bill of materials, weld list, etc.) from the isometric style and place them again. In the support case, isometric creation worked again afterward.
My iso bill of materials is too long for the sheet – is the bill of materials or the isometric split?
You want to define what happens with an overly long bill of materials: this is controlled by the table overflow in the isometric style. 1. Project Setup > Isometric DWG Settings > Set Up Iso Style, select the style. 2. Under "Table Overflow", choose whether the table data overflows onto a new drawing sheet or whether the isometric is split into two smaller isometrics. The option is only available for the "Isometric" drawing type, not for spool drawings. 3. Regenerate the isometric. If that is not enough, set split points specifically in the model. Advantage: the bill of materials and drawing remain legible and match the way of working in fabrication and installation.
A coupling or another asymmetrical component is displayed rotated on the isometric – what should I do?
In the configuration file in the “Isometric” project folder, add a line at the bottom of the “ASYMMETRIC COMPONENT LISTASYMMETRIC COMPONENT LIST Section in the AutoCAD Plant 3D isometric configuration: list of components with different connections (e.g. flange on one side, weld end on the other). Each line contains the iso type, SKEY and the end types at S1 and S2. Background and sources ›” with the Iso TYPE, SKEY, and the end types at S1 and S2. The S1/S2 order must match Port1/Port2 of the Iso symbol.
How do I show a custom identification on the isometric drawing instead of the tag?
If your own identifier should appear on the isometric instead of the tag, replace the Tag property with your own property for the relevant annotation in the iso style.
My Project Manager or other windows stay invisible – how do I reset the Plant 3D profile?
First back up your settings. Then delete the folders “Autodesk AutoCAD Plant 3D
How do I customize the title block, layers and lineweights of the isometric – and why don't the pipes adopt the lineweight from the layer?
Project Setup > Isometric DWG Settings > Title Block and Display > "Setup Title Block". The isometric template opens: the green area is the drawing area, the blue one the bill of materials area. The title block must be named "TitleBlock", otherwise it is missing in the preview. Isometrics use fields instead of attributes. In the Layer Manager you define colors and lineweights, e.g. so that pipes are displayed thicker than valves. If the pipes do not adopt the lineweight from the layer, check the current lineweight in the open template: set the system variable CELWEIGHTCELWEIGHT AutoCAD system variable: sets the lineweight of new objects; -1 = ByLayer, -2 = ByBlock, -3 = Default. Background and sources › to -1 (ByLayer), save the template and regenerate the isometric. The template is read in again each time the isometric is regenerated; orthographic drawings, by contrast, are not subsequently adapted to a changed template.
Isometric drawings cannot be generated and the log remains empty – will a reinstallation help?
For inexplicable errors (e.g. an isometric cannot be created, the log remains empty), a clean reinstallation often helps: uninstall completely and remove leftover folders, download fresh from the Autodesk account, install individually without an image or software distribution, temporarily disable the virus scanner, install AutoCAD first, then the other products, then all updates. The Windows account used for the installation needs write permissions on drive C:.
How do I adjust the frames around Iso annotations, e.g. so that the circle around the valve tag grows with it?
Under “Edit isometric symbols”, you change the “Anno…” blocks in the Block Editor. From version 2016, the frame shape and size adjustment can also be set under “Annotations”. For other cases, use IsoConfig.xml: styles prefixed with “S” (e.g. SWipeCircle) adapt to the content; first create the style under “AnnotationStyles” and then enter it in the ComponentScheme instead of “WipeCircle”.
How do I add an additional dimension on the isometric, e.g. across pipe and flange?
In the IsoConfig.xml of the isometric style, create a new filter with the elements “Pipe” and “Flange”. Then copy an existing AnchorPoint completely, rename it, and enter the new filter.
How do I pass wall thicknesses to the pipe stress analysis via PCF, and what interferes with the import?
In the iso.atr of the isometric style, add “EngineeringItemsWallThickness” as the last line (with a line break); component properties belong under BOM-ATTRIBUTES, project, drawing, and line group properties under ATTRIBUTESATTRIBUTES Section of the AutoCAD Plant 3D attribute file Iso.atr: it contains the project, drawing and line group properties for isometric and PCF output. Component properties are under BOM-ATTRIBUTES. Background and sources ›. The PCF contains end connections (END-CONNECTION-PIPELINEEND-CONNECTION-PIPELINE Entry in a PCF file: the line ends at this point at another pipeline. Some stress analysis programs cannot read these entries. Background and sources ›) that disturb some stress analysis programs – remove these sections in an editor before importing.
Why do some column headings in the Data Manager and in the Excel export carry the property name as a suffix (e.g. “Description-…”)?
You want clear column titles: The titles in the Data Manager and in the Excel export come from the display names of the properties. If custom properties have the same display name as existing ones (e.g. “Description”, “Type”), Plant 3D appends the property name to distinguish them. In the project configuration, assign unique display names (e.g. “Drive description”), reopen the Data Manager, and export again.
How do I have pipes automatically colored or placed on layers by piping spec or fluid?
Open Project Setup > Plant 3D DWG Settings > Layer and Color Settings. Create an assignment via New, e.g. by piping spec or fluid, and assign colors or layers; then set it as current. The rule applies to newly drawn objects and when the underlying property changes. For fluids, a separate, maintained fluid list must exist. If you use layers by fluid, also plan layer filters in the drawing template (DWT), otherwise the layer list quickly becomes confusing.
I can no longer place a bill of materials in my ortho drawing – what helps?
The ortho template is probably damaged. Take the supplied original ortho template (DWT) and copy your title block and border into it. Build new ortho drawings on this template.
A custom property is not annotated on the isometric despite being entered in the iso style – why?
If a custom property (e.g. on pipe supports) is not annotated on the isometric drawing despite an entry in the iso style, check the property name: an underscore in the name prevents the output. Create the property again without an underscore (e.g. SupportX instead of Support_X), and the annotation will appear.
The file names of my isometrics are cryptic – where do I define them?
The file name format of the isometrics is defined in Project Setup. If it is not defined, a cryptic name results.
How do I set up custom nozzles or manholes for nozzle selection?
In the content folder, under “CPakCPak Folders in the AutoCAD Plant 3D content directory (e.g. “CPak Common”) containing catalogs and their component files. The program expects these folders unchanged. Background and sources › Common”, open the Nozzle Catalog.acat in Spec Editor and add the desired nozzle and manhole sizes. They then appear in the nozzle selection window.
Where can you see how the line number of a pipeline is composed in Plant 3D?
You find the tag format in Project Setup under Plant 3D DWG Settings → Plant 3D Class Definitions → P3DP3D Short form for AutoCAD Plant 3D, e.g. before class names in the project setup (“P3D line group”). Background and sources › Line Group, Tag Format section. The default tag of the line group is the line number; further parts such as fluid or unit can be added. When routing, you choose nominal size and piping spec in the “Assign Tag” dialog and enter the line number. A new tag format only takes effect once it is selected as the default value in the “Tag Format Name” property.
I added an attribute to a block, but it does not appear – e.g. on the isometric. Why?
Existing block references do not automatically adopt new attributes. After changing the block, run the ATTSYNCATTSYNC AutoCAD command: applies changed attributes of a block to all places where this block is inserted. Background and sources › command for that block; the attributes are then present in all insertions.
Valves of different sizes appear on one line in the iso bill of materials – how do I separate them?
In the TableSetup, add the column “Long Description (Size)”, group the bill of materials, and enter “PartSizeLongDesc” as the grouping column in the IsoConfig.xml.
Fields in the Iso title block stay empty – what is the cause?
Every property that is to appear in the Iso.dwt, in annotations or in dimensions must be entered in the Iso.atr: project, drawing and line group properties under ATTRIBUTES, component properties under BOM-ATTRIBUTES.
How does Plant 3D calculate the insulation weight of a component automatically instead of just entering a default value?
You want the weight of the insulation per component without manual work: create a calculated property. 1. Project Manager → right-click the project → Project Setup → Plant 3D DWG Settings → Plant 3D Class Definitions → Piping and Equipment → appropriate class (e.g. Pipe) → Add; select "Calculated" as the type, format Double (the property name without spaces). 2. In the expression, convert text values to numbers with ToNumber and round with Round. Pipe (cut length in mm, weight per meter in your field
For some components the "Status" property is empty instead of "New" – how do I fix this?
You want all components to carry a valid status: 1. Open Project Setup and, in the class definitions of the affected component class, check the default value of the "Status" property. 2. If "New" is not entered there, override the default value and set it to "New". 3. For components that have already been drawn, create a view with the "Status" column in the Data Manager, search for the empty values and fill them in collectively, e.g. by exporting to Excel and then importing. Back up the project first. Advantage: reports and filters that evaluate by status capture all components again.
My changes to the isometric XML file are gone again after a restart. Why?
Plant 3D rewrites the configuration files on exit. Therefore close Plant 3D before you edit XML files in the project folder "Isometric" with a text editor. Save in the editor with Ctrl+S and close the file or the tab in the editor so that the change is really written to disk. Only then restart Plant 3D and regenerate the isometric.
How do I change the isometric symbol of a valve or create my own actuator symbol?
Project Setup > Isometric DWG Settings > Symbols and References > "Edit Isometric Symbols". In the Block Editor, open an existing symbol, save it under a new, unique name with "Save Block As", then modify it. The connection points (Port 1, Port 2 …) and, for valves, CP and Operator must be preserved – their names are evaluated. The assignment of symbol key (SKEY) to block is made in the XML file in the project's "Isometric" folder. Each code may only occur once; the first entry found wins.
How do I get the support tag onto the isometric?
In the IsoConfig.xml of the style, under ComponentScheme, find the “Static annotations” and, in the section “PipeRunComponent DataSolver generated property schemes (start)”, add an annotation with Filter="Support" and Fields="TAG" (e.g. Alignment="FlatHorizontal", LeaderStyle="Always"). The AnnotationStyle (WipeCircle, Standard, Diamond) determines the frame.
The designation appears twice in the isometric bill of materials – why?
In the table setup of the bill of materials, both long description and description are probably included as columns or rows. Remove one of the two fields in the isometric style.
On the isometric of an insulated line, "Insul" or "Not Insul" appears – how do I suppress this note?
You want to control the insulation notes on the isometric: the note comes from the "InsulationLimit" property schema of the isometric style, which labels the insulation limits. If it is not wanted for technical reasons: 1. Close Plant 3D and first back up the IsoConfig.xml of the isometric style used in the "Isometric" project folder. 2. Delete the "InsulationLimit" property schema in the file. 3. Save and close the file, start Plant 3D and regenerate the isometric. Advantage: the setting applies to all isometrics of this style – there is no need to delete the note manually on every finished isometric.
An instrument sitting directly on an olet gets no item number on the isometric – why?
In the project configuration, under Isometric DWG Settings › Themes › Branch, disable the option “Offline Instrument Connection”. After that, an instrument seated directly in the olet also receives a part number.
How do I get the operating pressure and temperature of the line group into the valve list?
Create properties on the valves that receive these values from the line via an acquisition rule, and run PLANTREFRESHACQPROPERTYPLANTREFRESHACQPROPERTY Command in AutoCAD Plant 3D and AutoCAD P&ID: updates acquired properties – e.g. the line number from an acquisition rule – on objects already drawn. Background and sources ›. They are then available in the Report Creator.
The questions come from our training courses and support sessions – anonymized, without customer or project data. Menu paths refer to current German program versions and may differ by version; the answers do not replace checking in your own project.

Before you go …
Don't miss any training dates, C³ invitations and news on AutoCAD Plant 3D and P&ID.
Our newsletter only arrives when there's something important – concise and with tips from practice.
Technically responsible: A. Seitz, Managing Director of A. Seitz Ingenieur GmbH (plant design, AutoCAD Plant 3D).
Terms, background and sources 46 terms on this page
Brief explanations for reference. They do not replace the standard or code itself.
- bar – Unit of pressure
Unit of pressure: 1 bar = 100,000 Pa = 0.1 MPa. In plant engineering, it usually refers to the gauge pressure relative to the surroundings (often “barg” or, in German, “bar ü”).
- DWT – Drawing template
AutoCAD template file (drawing template): new drawings take their layers, styles and settings from it.
- R&I – Piping and instrumentation diagram
Flow diagram showing all pipes, valves, equipment and instrumentation of a plant (P&ID, Piping and Instrumentation Diagram).
Symbols and drawing rules: DIN EN ISO 10628-1 and -2. Identification letters for instrumentation: DIN EN 62424 or ISA-5.1.
- DWG – AutoCAD drawing format
AutoCAD file format for drawings and 3D models; AutoCAD Plant 3D and AutoCAD P&ID also save in this format.
- FASTSHADEDMODE
AutoCAD system variable: turns the newer cross-platform 3D graphics system on (1) or off (0). The variable no longer exists in AutoCAD 2027.
- PCF – Piping Component File
Text file with which AutoCAD Plant 3D passes piping data to the isometric generator and to other programs.
- ISO – International Organization for Standardization
International Organization for Standardization in Geneva: it develops standards that apply worldwide (ISO standards).
ISO was founded in 1947. Its members are the national standards bodies; for Germany, this is DIN.
- PLANTINSULATIONMODE
AutoCAD Plant 3D system variable: determines whether insulation on pipes is displayed.
- IFC – Industry Foundation Classes
Open exchange format for building and plant models (BIM), standardized as ISO 16739.
- EXPORTTOAUTOCAD
Command in AutoCAD Plant 3D and AutoCAD P&ID: saves a copy of the drawing in which the plant objects are converted into simple AutoCAD objects – readable without plant software.
- MEP – Mechanical, Electrical and Plumbing
Collective English term for building services: heating and ventilation, electrical and plumbing. Roughly equivalent to the German TGA; AutoCAD MEP is the matching AutoCAD toolset.
- LOG
Log file: a program writes into it what it has done and which errors occurred.
- F2
Function key in AutoCAD: shows and hides the extended text window with the command history – where, e.g., audit reports appear.
- MB, GB, TB – Megabyte, gigabyte, terabyte
Units for data volumes: 1 GB (gigabyte) = 1,000 MB (megabytes), 1 TB (terabyte) = 1,000 GB.
Operating systems sometimes calculate with 1,024 instead of 1,000. Strictly speaking these units are called MiB, GiB and TiB (standard IEC 80000-13).
- NWC – Navisworks cache file
File that Navisworks creates when loading a foreign file so that it loads faster the next time.
- NWD – Navisworks file (published)
Navisworks file in which all models are stored permanently – for sharing, also with the free Navisworks Freedom.
- FILEDIA
AutoCAD system variable: determines whether file dialogs open (1) or AutoCAD asks for file names on the command line (0).
- BOM – Bill of Materials
Bill of Materials – parts or material list. In AutoCAD Plant 3D the BOM-ATTRIBUTES section of Iso.atr defines the component properties on the isometric.
- PLANTAUDIT
Command in AutoCAD Plant 3D and AutoCAD P&ID: checks the drawing against the project database and fixes errors in the synchronisation between the two.
- PN – Nominal pressure rating
Designation for the pressure rating of flanges and valves (Pressure Nominal), e.g. PN 16. It corresponds roughly to the allowable pressure in bar at room temperature; at higher temperatures, less is allowed.
Specified in DIN EN 1333. The pressure-temperature ratings for each material are given in the component standards, e.g. DIN EN 1092-1 for steel flanges.
- INSUNITS
AutoCAD system variable: sets the drawing unit for inserting, e.g. 4 = millimetres, 6 = metres. AutoCAD uses it to scale blocks and references when inserting.
- PLANTCOPYLINENUMBER
AutoCAD Plant 3D system variable: determines whether the line number is kept (ON) or not (OFF) when copying from an existing line – in the P&ID and in the 3D model.
- MText – Multiline Text
Paragraph text in AutoCAD: multi-line text as one object, with its own formatting per character.
- PLANTPARTCONVERT
AutoCAD Plant 3D command: turns an AutoCAD block into a piping component by adding connections (ports).
- PNG
Portable Network Graphics: image format with lossless compression.
- PLANTISOSPLITPOINTS
AutoCAD Plant 3D command: transfers the split points of an isometric into the 3D model as fixed points (“Convert split points”).
- S1, S2
First and second connection (port 1, port 2) of a component in AutoCAD Plant 3D, e.g. in the catalog and in the isometric configuration.
- PLANTEQUIPMENTCONVERT
AutoCAD Plant 3D command: converts a 3D model made of AutoCAD objects into equipment with nozzles and tag (“Convert Equipment”).
- BOP – Bottom of Pipe
Bottom of Pipe – lower edge of the pipe. Lines with the same BOP rest at the same height on a pipe rack, for example, even with different nominal sizes.
- PLANTDYNAMICTOOLPALETTE
AutoCAD Plant 3D command: creates a tool palette with the components of the current piping spec.
- DIMLFAC
AutoCAD system variable: scale factor for linear dimensions: the measured value is multiplied by it before it appears as the dimension text.
- CADmep
Autodesk Fabrication CADmep: add-on for AutoCAD for designing ventilation, piping and electrical installations with fabrication-accurate components.
- AEC – Architecture, Engineering & Construction
English for architecture, engineering and construction. At Autodesk this is the name of the “AEC Collection”, which includes AutoCAD with the AutoCAD Plant 3D toolset, Revit and Navisworks.
- DN – Nominal size (DN)
Designation for the size of pipes, fittings and valves (Diameter Nominal). It is roughly the inside diameter in millimeters but is not an exact dimension.
Specified in DIN EN ISO 6708. Which outside diameter belongs to a DN is defined in the dimensional standards, e.g. DIN EN 10220 for steel pipes.
- PLANTINSULATIONUSEPARTLAYER
AutoCAD Plant 3D system variable: determines whether the insulation is on the pipe's layer (1) or on its own layer (0).
- PLANTINSULATIONCOLOR
AutoCAD Plant 3D system variable: sets the colour of the displayed insulation; 256 = ByLayer.
- PLANTINSULATIONTRANSPARENCY
AutoCAD Plant 3D system variable: sets the transparency of the displayed insulation; -1 = ByLayer.
- SKEY – Symbol key (SKEY)
Four-character symbol key for the isometric: the first two characters give the component type, the last two the end connection, e.g. VTFL = gate valve with flanges.
- ASYMMETRIC COMPONENT LIST
Section in the AutoCAD Plant 3D isometric configuration: list of components with different connections (e.g. flange on one side, weld end on the other). Each line contains the iso type, SKEY and the end types at S1 and S2.
- CELWEIGHT
AutoCAD system variable: sets the lineweight of new objects; -1 = ByLayer, -2 = ByBlock, -3 = Default.
- ATTRIBUTES
Section of the AutoCAD Plant 3D attribute file Iso.atr: it contains the project, drawing and line group properties for isometric and PCF output. Component properties are under BOM-ATTRIBUTES.
- END-CONNECTION-PIPELINE
Entry in a PCF file: the line ends at this point at another pipeline. Some stress analysis programs cannot read these entries.
- CPak
Folders in the AutoCAD Plant 3D content directory (e.g. “CPak Common”) containing catalogs and their component files. The program expects these folders unchanged.
- P3D
Short form for AutoCAD Plant 3D, e.g. before class names in the project setup (“P3D line group”).
- ATTSYNC
AutoCAD command: applies changed attributes of a block to all places where this block is inserted.
- PLANTREFRESHACQPROPERTY
Command in AutoCAD Plant 3D and AutoCAD P&ID: updates acquired properties – e.g. the line number from an acquisition rule – on objects already drawn.
Sources and origins
- BIPM – International System of Units (SI) (for bar)
- Autodesk Help (for DWT, NWC, NWD, MText, S1, S2, BOP, SKEY, ASYMMETRIC COMPONENT LIST, ATTRIBUTES, END-CONNECTION-PIPELINE, CPak, P3D)
- ISO – International Organization for Standardization (for R&I, ISO, IFC)
- IEC – International Electrotechnical Commission (for R&I, MB, GB, TB)
- Autodesk – DWG (for DWG)
- Autodesk Help: FASTSHADEDMODE (System Variable) (for FASTSHADEDMODE)
- Autodesk – AutoCAD Plant 3D Help (for PCF)
- Autodesk Help: PLANTINSULATIONMODE (for PLANTINSULATIONMODE)
- buildingSMART International (for IFC)
- Autodesk Help: EXPORTTOAUTOCAD (for EXPORTTOAUTOCAD)
- Autodesk (for MEP, AEC)
- Wikipedia: Log file (for LOG)
- Autodesk Help: Function Key Reference (for F2)
- BIPM – SI prefixes (for MB, GB, TB)
- Autodesk Help: FILEDIA (System Variable) (for FILEDIA)
- Wikipedia: Bill of materials (for BOM)
- Autodesk Help: PLANTAUDIT (for PLANTAUDIT)
- CEN and CENELEC – European standardization (for PN)
- DIN – German Institute for Standardization (for PN, DN)
- Autodesk Help: INSUNITS (System Variable) (for INSUNITS)
- Autodesk Help: PLANTCOPYLINENUMBER (for PLANTCOPYLINENUMBER)
- Autodesk Help: PLANTPARTCONVERT (for PLANTPARTCONVERT)
- Wikipedia: Portable Network Graphics (for PNG)
- Autodesk Help: To Save Iso Split Points in the 3D Model (for PLANTISOSPLITPOINTS)
- Autodesk Help: PLANTEQUIPMENTCONVERT (for PLANTEQUIPMENTCONVERT)
- Autodesk Help: PLANTDYNAMICTOOLPALETTE (for PLANTDYNAMICTOOLPALETTE)
- Autodesk Help: DIMLFAC (System Variable) (for DIMLFAC)
- Autodesk Help: CADmep Commands List (for CADmep)
- ISO 6708 – Pipework components, definition and selection of DN (for DN)
- Autodesk Help: PLANTINSULATIONUSEPARTLAYER (for PLANTINSULATIONUSEPARTLAYER)
- Autodesk Help: PLANTINSULATIONCOLOR (for PLANTINSULATIONCOLOR)
- Autodesk Help: PLANTINSULATIONTRANSPARENCY (for PLANTINSULATIONTRANSPARENCY)
- Autodesk Help: Commands for Object Properties (for CELWEIGHT)
- Autodesk Help: ATTSYNC (Command) (for ATTSYNC)
- Autodesk Community: AutoCAD Plant 3D Forum (for PLANTREFRESHACQPROPERTY)